A-Z Manufacturers (Pliteq) |  CAWS Index

View larger image of GenieClip-LB2 from PliteqGenieClip-LB2

A uni-body moulded rubber and steel part with extended bracket, used when superior sound control is required in multi-family housing, high-rises or commercial buildings. The resilient sound isolation clip with extended steel bracket can be used as a standalone system or in conjunction with a GenieClip wall or ceiling system. It extends or reduces the profile space between the gypsum board layer and floor joists or wall studs, and provides support at the wall termination of furring channels.Features and benefits:Significantly improves low and high frequency sound control performance.Substantially reduces impact noise in floor-ceiling assemblies.Allows for thinner (and even no) resilient mat used in certain floor-ceiling assemblies.Dimensions (l x w x h):64 x 41 x 124 mm.Minimum tensile strength (ASTM D412, Die C):11.2 MPa.Elongation at break (ASTM D573):454% minimum.Type A Hardness (ASTM D2240):37 durometer.Dynamic stiffness (ASTM D5992, D4473, D4065):11.3 N/mm.Laboratory sound transmission class:Specified wall or floor ceiling assembly must be tested in a UKAS accredited laboratory and comply with BS EN ISO standards.Field sound transmission class:Specified wall or floor-ceiling assembly must meet requirement as stated by building standards and/ or acoustic consultant.Temperature stability:-40 to +115°C.Performance:Consult manufacturer's literature for details.

A uni-body moulded rubber and steel part with extended bracket, used when superior sound control is required in multi-family housing, high-rises or commercial buildings. The resilient sound isolation clip with extended steel bracket can be used as a standalone system or in conjunction with a GenieClip wall or ceiling system. It extends or reduces the profile space between the gypsum board layer and floor joists or wall studs, and provides support at the wall termination of furring channels.

Features and benefits:

  • Significantly improves low and high frequency sound control performance.
  • Substantially reduces impact noise in floor-ceiling assemblies.
  • Allows for thinner (and even no) resilient mat used in certain floor-ceiling assemblies.

More about GenieClip-LB2:
As standard - Options

GenieClip-LB2
 Manufacturer:
Pliteq.
  -Web:www.pliteq.com.
  -Tel:+44 (0)7591205089.
  -Product reference:
GenieClip-LB2.


top ^

Guidance

for GenieClip-LB2

from Pliteq

More about GenieClip-LB2: As standard - Options

As standard

Dimensions (l x w x h):

64 x 41 x 124 mm.

Minimum tensile strength (ASTM D412, Die C):

11.2 MPa.

Elongation at break (ASTM D573):

454% minimum.

Type A Hardness (ASTM D2240):

37 durometer.

Dynamic stiffness (ASTM D5992, D4473, D4065):

11.3 N/mm.

Laboratory sound transmission class:

Specified wall or floor ceiling assembly must be tested in a UKAS accredited laboratory and comply with BS EN ISO standards.

Field sound transmission class:

Specified wall or floor-ceiling assembly must meet requirement as stated by building standards and/ or acoustic consultant.

Temperature stability:

-40 to +115°C.

Options

Performance:

Consult manufacturer's literature for details.

Further Information

Literature:

RIBA Product Selector

Additional information may be available for Pliteq from ribaproductselector.com.

Contacts:

www.pliteq.com

jbligh@pliteq.com

T: +44 (0)7591205089

F: +44 (0)1223 257800