A-Z Manufacturers (Gilgen Door Systems UK Ltd) |  CAWS Index

View larger image of SLX/D Hermetically Sealed Sliding Door from Gilgen Door Systems UK LtdSLX/D Hermetically Sealed Automatic Sliding Door

Tested for 1 million cycles SLX sliding door operators offer proven reliability as well as the integration of a number of technological advancements such as CanBus technology for enhanced operational safety and blue tooth wireless technology for easier access and control. The SLX/D with its unique patented pivot mechanism is the ideal choice where air tight door and hands free access are a priority for guaranteed optimum hygiene or sound proofing. It is particularly suitable for doors in hospitals, operating rooms, laboratories, music rooms, pharmaceutical and food industries.All equipment is installed by Automatic Door Suppliers Association (ADSA) accredited engineers.Drive system:SLX Sliding door drive unit with pivoting mechanism that enables the sliding wing to be simultaneously lowered and pressed against the door frame during the closing motion.Integrates Bluetooth wireless control technology and powerful, near silent drive into a very slender profile. System components are connected via a CANbus, which not only guarantees smooth and reliable operation, but also facilitates constant communication with the processor to ensure optimum operational safety.Safety:Combined presence and activation sensing devices ensure door opening distances are in accordance with BS EN 16005, prevent doors closing on pedestrians within the threshold area and provide a signal to the door control system, thereby optimising pedestrian safety.Rear edge sensors (electro sensitive protection equipment, ESPE) complying with BS EN 16005 are located within the door operator to maintain back of door safety and protect pedestrians against crushing edges at the main closing edge.Fail-safe system (battery back-up) enables up to 30 minutes operation (subject to use) in the event of a mains failure. The fail safe system is automatically tested at least once every 24 hours.Fire alarm interface connection enables door leaves to fail safe to open in the event of an emergency. In compliance with BS EN 16005 door sets with a clear opening width of up to 2000 mm open by at least 80% within 3 seconds after activation by the activators in the escape direction (or within 5 seconds in the event of the loss of power.)Water resistance:IP20 rating.Operation:24 V DC motor with microprocessor controller which allows extensive options for opening width, electric locking, summer/ winter modes, exit only, manual control, speed of opening and the length of time the door is open. Power requirements:230 V single phase. A 13 A live neon-lit fused spur supply, protected by a 30 mA RCD must be provided prior to installation. In order to comply with BS EN 16005 the mains connection must be capable of disconnection to prevent unintentional and unauthorised reactivation.Door panel weight (maximum):120 kg.Control:Portable Bedix wireless control unit: Designed to enable selection of operating modes and configure parameters. Simple menu based controls. No fixed location required. Password protected.D-Bedix hard wired programming key pad with digital display. Designed for installing a central control panel. Configured or Automatic – Night – Exit – Open door operating modes.F Key: Each unit can be programmed to restrict access to areas which normally need to be kept locked.Operation:Additionally, the door allows for fitting of door position switches, fire or smoke alarm signals and voice message systems to assist partially sighted people and integrates with access control systems.X-Ray shielding:With lead insert and special window.Product literature:http://www.ribaproductselector.com/documentdetails.aspx?ci=03743&f=COL264757.pdf&pg=10CE approval0TUV NORD10DIN18650-1 and DIN 18650-2 (2005 and 2010)10EN 12207 Class 2 Air permeability10ISO 9001: 2008

Tested for 1 million cycles SLX sliding door operators offer proven reliability as well as the integration of a number of technological advancements such as CanBus technology for enhanced operational safety and blue tooth wireless technology for easier access and control.

The SLX/D with its unique patented pivot mechanism is the ideal choice where air tight door and hands free access are a priority for guaranteed optimum hygiene or sound proofing. It is particularly suitable for doors in hospitals, operating rooms, laboratories, music rooms, pharmaceutical and food industries.

All equipment is installed by Automatic Door Suppliers Association (ADSA) accredited engineers.

More about SLX/D Hermetically Sealed Automatic Sliding Door:
As standard - Options - Approvals

SLX/D Hermetically Sealed Automatic Sliding Door
 Manufacturer:
Gilgen Door Systems UK Ltd.
  -Web:www.gilgendoorsystems.co.uk.
  -Tel:+44 (0)800 316 6994.
  -Product reference:
SLX/D Hermetically Sealed automatic Sliding Door.
 Door:
  -Configuration:
[Single Slide left].
[Single Slide right].
  -Clearance width:
[ ______ ] - 800–2000 mm; insert requirements.
  -Height:
[ ______ ] - 2100–2400 mm (optimum).
  -Finish:
[Formica high pressure laminate].
[Polished stainless steel].
[Perstop, RAL colour]. - Insert colour requirements.
 Inset window glazing:
[6 mm laminated safety glass].
[24 mm double glazed].
[Windows with UK absorbing foil materials].
[Windows with blinds or pressure compensation bars].
 Sound insulation:
[ ______ ] - Up to 32 dB possible; consult manufacturer and insert requirements.
 X-Ray shielding:
[Not required].
[Required].
 Frame:
[Single]. - Made from aluminium profile sections.
[Double]. - Aluminium profile sections with intermediate section to match door wing.
 Control:
[D-Bedix hard wired control unit].
[F Key].
[Large optical push pad].
[Portable Bedix wireless control unit].
[Movement sensors].
[Manual door handle].


top ^

Guidance

for SLX/D Hermetically Sealed Automatic Sliding Door

from Gilgen Door Systems UK Ltd

More about SLX/D Hermetically Sealed Automatic Sliding Door: As standard - Options - Approvals

As standard

Drive system:

  • SLX Sliding door drive unit with pivoting mechanism that enables the sliding wing to be simultaneously lowered and pressed against the door frame during the closing motion.
  • Integrates Bluetooth wireless control technology and powerful, near silent drive into a very slender profile. System components are connected via a CANbus, which not only guarantees smooth and reliable operation, but also facilitates constant communication with the processor to ensure optimum operational safety.

Safety:

  • Combined presence and activation sensing devices ensure door opening distances are in accordance with BS EN 16005, prevent doors closing on pedestrians within the threshold area and provide a signal to the door control system, thereby optimising pedestrian safety.
  • Rear edge sensors (electro sensitive protection equipment, ESPE) complying with BS EN 16005 are located within the door operator to maintain back of door safety and protect pedestrians against crushing edges at the main closing edge.
  • Fail-safe system (battery back-up) enables up to 30 minutes operation (subject to use) in the event of a mains failure. The fail safe system is automatically tested at least once every 24 hours.
  • Fire alarm interface connection enables door leaves to fail safe to open in the event of an emergency. In compliance with BS EN 16005 door sets with a clear opening width of up to 2000 mm open by at least 80% within 3 seconds after activation by the activators in the escape direction (or within 5 seconds in the event of the loss of power.)

Water resistance:

IP20 rating.

Operation:

24 V DC motor with microprocessor controller which allows extensive options for opening width, electric locking, summer/ winter modes, exit only, manual control, speed of opening and the length of time the door is open.

Power requirements:

230 V single phase. A 13 A live neon-lit fused spur supply, protected by a 30 mA RCD must be provided prior to installation. In order to comply with BS EN 16005 the mains connection must be capable of disconnection to prevent unintentional and unauthorised reactivation.

Door panel weight (maximum):

120 kg.

Options

Control:

  • Portable Bedix wireless control unit: Designed to enable selection of operating modes and configure parameters. Simple menu based controls. No fixed location required. Password protected.
  • D-Bedix hard wired programming key pad with digital display. Designed for installing a central control panel. Configured or Automatic – Night – Exit – Open door operating modes.
  • F Key: Each unit can be programmed to restrict access to areas which normally need to be kept locked.

Operation:

  • Additionally, the door allows for fitting of door position switches, fire or smoke alarm signals and voice message systems to assist partially sighted people and integrates with access control systems.

X-Ray shielding:

With lead insert and special window.

Approvals

  • CE approval .
  • TUV NORD .
  • British Standards Institution: DIN18650-1 and DIN 18650-2 (2005 and 2010). British Standards Institution
  • British Standards Institution: EN 12207 Class 2 Air permeability. British Standards Institution
  • British Standards Institution: ISO 9001: 2008. British Standards Institution

Further Information

Literature:


RIBA CPD

CPD information is available for Gilgen Door Systems UK Ltd from ribacpd.com.

RIBA Product Selector

Additional information may be available for Gilgen Door Systems UK Ltd from ribaproductselector.com.

Contacts:

www.gilgendoorsystems.co.uk

info@gilgendoorsystems.co.uk

T: +44 (0)800 316 6994

F: +44 (0)800 316 6995

Drag work item to add to schedule