Gilgen heavy duty steel vertical rolling shutter doors – include enhanced levels of tested security resistance, energy conservation and sound reduction. These products also provide compliance with insurance, Police Preferred specifications and Secured by Design standards. The doors comply with BS EN 13241-1. SR2 is medium security to protect against determined opportunist attack.Applications:Shutters with external direct drive motors are normally used on buildings with three phase mains power supply, such as industrial applications which may require medium to heavy usage for example vehicle access doors.Shutters with single phase motors are suitable for applications which have limited head space or require a compact appearance and buildings that are limited to a single phase mains power supply, for example shop fronts, commercial entrances or vehicle access routes with low traffic requirements.Security rating: LPS 1175 SR 2 (issue 7) and Secured by Design approved.Arrangement: Internal face fixed.Product reference: - SR2–INS–DD: Maximum door area: 64 m².Curtain: Curved micro ribbed faces, insulated core.Operation: External direct drive three phase 415 V AC motor and neutral supply complete with manual override hand chain. Motor drive duty rating: Three phase, Class S3 – 65%.Thermal insulation (U-value): 3.8 W/m²K.- SR2–INS–TM: Maximum door area: 25 m². Curtain: Curved micro ribbed faces, insulated core. Operation: Single phase 230 V AC; tubular motor complete with manual override hand crank. Motor drive duty rating: Single phase tubular motor and controls, Class S3 – 25%. Thermal insulation (U-value): 3.8 W/m²K.- SR2–SS–DD:Maximum door area: 64 m².Curtain: Single skin concave galvanized steel lath.Operation: Three phase; direct drive (DD) 415V AC motor complete with emergency hand chain. Motor drive duty rating: Three phase, Class S3 – 65%. Fire performance (to DIN 4102): Class A2 – door section element materials are non-flammable.- SR2–SS–TM:Maximum door area: 20 m².Curtain: Single skin concave galvanized steel lath.Operation: Single phase 230 V AC; tubular motor complete with manual override hand crank. Motor drive duty rating: Single phase tubular motor and controls, Class S3 – 25%. Fire performance (to DIN 4102): Class A2 – door section element materials are non-flammable.Performance:Security rating; Loss Prevention Standard 1175 Issue 7 Security Rating 2, meeting all the requirements defined in sections 3 and 4 of the Loss Prevention Certification Board test standard.Gilgen Door Systems understand that security risk ratings can be different for each application. The above SR ratings are provided for guidance purposes only and it is the responsibility of the specifier or customer to make the final interpretation and decision.Approved by Secured by Design – The UK official Police design initiative to reduce crime governed by The Association of Chief Police Officers. Wind pressure (BS EN 12424): Class 3 Beaufort 11, 73 mph, 700 N/m².Sound reduction (Rw): 16 dB. Static load (weight of whole door assembly): Approximately 30 kg/m².Controls:A comprehensive range of vehicle detectors, hand transmitters, receiver units, push-button controls, key switches, safety edges, photocells, signal lights and digital control units are also available as alternatives or in addition to the standard control units. Contact manufacturer for further information.Safety activation: Dead man operation as standard which requires the operator to apply constant pressure to the door operating device (key switch or push button) as per BS EN 12453-5.5.1.Remote or automatic door controls – minimum requirements, impact sensitive safety edge/ non contact safety beam.Accessories:Three-sided head cover; available for applications which may require improved aesthetic appearance or protection from local environmental conditions. Removable motor cover; available to cover the exposed part of the drive motor which projects outside of the three sided head cover on the three phase design.For applications which require a more substantial seal against water ingress, a suitably designed structural threshold arrangement is recommended – contact Gilgen for advice.Product literature:http://www.ribaproductselector.com/documentdetails.aspx?ci=03743&f=COL264135.pdf&pg=3

Gilgen heavy duty steel vertical rolling shutter doors – include enhanced levels of tested security resistance, energy conservation and sound reduction. These products also provide compliance with insurance, Police Preferred specifications and Secured by Design standards. The doors comply with BS EN 13241-1. SR2 is medium security to protect against determined opportunist attack.

Applications:

  • Shutters with external direct drive motors are normally used on buildings with three phase mains power supply, such as industrial applications which may require medium to heavy usage for example vehicle access doors.
  • Shutters with single phase motors are suitable for applications which have limited head space or require a compact appearance and buildings that are limited to a single phase mains power supply, for example shop fronts, commercial entrances or vehicle access routes with low traffic requirements.

More about Gilgen Rolegard High Security Shutters SR2:
As standard - Options

Gilgen Rolegard High Security Shutters SR2
 Manufacturer:
Gilgen Door Systems UK Ltd.
  -Web:www.gilgendoorsystems.co.uk.
  -Tel:+44 (0)800 316 6994.
  -Product reference:
[Gilgen Rolegard High Security SR2–INS–DD].
[Gilgen Rolegard High Security SR2–INS–TM].
[Gilgen Rolegard High Security SR2–SS–DD].
[Gilgen Rolegard High Security SR2–SS–TM].
 Size (w x h) :
[ ______ ] - 2–8 m; insert requirements.
 Colour/ finish:
[Galvanized only]. - As standard.
[Painted to BS 4800, colour]. - Insert requirements from RAL colour range.
 Frame/ guides:
[Galvanized heavy duty reinforced steel].
[Carbon steel plate BZP coated]. - Insert requirements.
 Control:
[ ______ ] - Contact manufacturer for details and insert requirements.
 Safety:
[Dead man].
[Contact safety edge].
[Non-contact safety beam].
[Non-contact safety light curtain].
 Activation:
[Building Management System integration]. - For use with SR2–SS–DD only.
[Door status monitoring controller]. - For use with SR2–SS–DD only.
[Infrared vehicle/ person detection scanner].
[Internal digital keypad].
[Internal key switch].
[Internal lockable push button].
[Remote push button].
[Remote radio control].
 Accessories:
[None].
[Galvanized sheet steel motor cover]. - For shutters with external direct drive motors only.
[Galvanized three sided, sheet steel hood cover].
[Weather seal to bottom edge of shutter].


top ^

Guidance

for Gilgen Rolegard High Security Shutters SR2

from Gilgen Door Systems UK Ltd

More about Gilgen Rolegard High Security Shutters SR2: As standard - Options

As standard

Security rating:

LPS 1175 SR 2 (issue 7) and Secured by Design approved.

Arrangement:

Internal face fixed.

Options

Product reference:

- SR2–INS–DD:

  • Maximum door area: 64 m².
  • Curtain: Curved micro ribbed faces, insulated core.
  • Operation: External direct drive three phase 415 V AC motor and neutral supply complete with manual override hand chain. Motor drive duty rating: Three phase, Class S3 – 65%.
  • Thermal insulation (U-value): 3.8 W/m²K.

- SR2–INS–TM:

  • Maximum door area: 25 m².
  • Curtain: Curved micro ribbed faces, insulated core.
  • Operation: Single phase 230 V AC; tubular motor complete with manual override hand crank. Motor drive duty rating: Single phase tubular motor and controls, Class S3 – 25%.
  • Thermal insulation (U-value): 3.8 W/m²K.

- SR2–SS–DD:

  • Maximum door area: 64 m².
  • Curtain: Single skin concave galvanized steel lath.
  • Operation: Three phase; direct drive (DD) 415V AC motor complete with emergency hand chain. Motor drive duty rating: Three phase, Class S3 – 65%.
  • Fire performance (to DIN 4102): Class A2 – door section element materials are non-flammable.

- SR2–SS–TM:

  • Maximum door area: 20 m².
  • Curtain: Single skin concave galvanized steel lath.
  • Operation: Single phase 230 V AC; tubular motor complete with manual override hand crank. Motor drive duty rating: Single phase tubular motor and controls, Class S3 – 25%.
  • Fire performance (to DIN 4102): Class A2 – door section element materials are non-flammable.

Performance:

  • Security rating; Loss Prevention Standard 1175 Issue 7 Security Rating 2, meeting all the requirements defined in sections 3 and 4 of the Loss Prevention Certification Board test standard.
  • Gilgen Door Systems understand that security risk ratings can be different for each application. The above SR ratings are provided for guidance purposes only and it is the responsibility of the specifier or customer to make the final interpretation and decision.
  • Approved by Secured by Design – The UK official Police design initiative to reduce crime governed by The Association of Chief Police Officers.
  • Wind pressure (BS EN 12424): Class 3 Beaufort 11, 73 mph, 700 N/m².
  • Sound reduction (Rw): 16 dB.
  • Static load (weight of whole door assembly): Approximately 30 kg/m².

Controls:

A comprehensive range of vehicle detectors, hand transmitters, receiver units, push-button controls, key switches, safety edges, photocells, signal lights and digital control units are also available as alternatives or in addition to the standard control units. Contact manufacturer for further information.

Safety activation:

  • Dead man operation as standard which requires the operator to apply constant pressure to the door operating device (key switch or push button) as per BS EN 12453-5.5.1.
  • Remote or automatic door controls – minimum requirements, impact sensitive safety edge/ non contact safety beam.

Accessories:

  • Three-sided head cover; available for applications which may require improved aesthetic appearance or protection from local environmental conditions.
  • Removable motor cover; available to cover the exposed part of the drive motor which projects outside of the three sided head cover on the three phase design.
  • For applications which require a more substantial seal against water ingress, a suitably designed structural threshold arrangement is recommended – contact Gilgen for advice.

Further Information

Literature:


RIBA CPD

CPD information is available for Gilgen Door Systems UK Ltd from ribacpd.com.

RIBA Product Selector

Additional information may be available for Gilgen Door Systems UK Ltd from ribaproductselector.com.

Contacts:

www.gilgendoorsystems.co.uk

info@gilgendoorsystems.co.uk

T: +44 (0)800 316 6994

F: +44 (0)800 316 6995

Drag work item to add to schedule

top ^

 
NBS Plus
NBS Building, online library, 18 December 2017