A-Z Manufacturers (Gilgen Door Systems UK Ltd) |  CAWS Index

View larger image of EI30 Fire Rated Automatic Sliding Door System from Gilgen Door Systems UK LtdEI30 Fire Rated Automatic Sliding Door System

The EI30 fire rated automatic sliding door system provides convenient, barrier-free access in day-to-day situations, while offering robust flame protection and easy entry for the emergency services in the event of a fire. The system can be used to divide rooms into compartments providing reliable fire protection along with a heat-shield for up to 30 minutes. If a fire alarm is activated, the automatic sliding fire-door can be opened manually like a conventional swing door in order to provide an emergency exit. Built-in closing mechanisms ensure that the door shuts again to provide a fire barrier once it has performed its emergency-exit function.All equipment is installed by Automatic Door Suppliers Association (ADSA) accredited engineers.Door profile:73 mm thick.Door panel weight:Standard SLX drive: 2 x 120 kg.Standard SLX drive with booster: 2 x 150 kg.SLX V drive with dual motors: 2 x 240 kg.Drive system:EI30 sliding door drive system integrates Bluetooth wireless control technology and a powerful, near silent drive into a slender profile. System components are connected via a can-bus, which not only guarantees smooth and reliable operation, but also facilitates constant communication with the processor to ensure optimum operational safety.Safety:Combined presence and activation sensing devices ensure door opening distances are in accordance with BS EN 16005, prevent doors closing on pedestrians within the threshold area and provide a signal to the door control system, thereby optimising pedestrian safety.Rear edge sensors (electro sensitive protection equipment, ESPE) complying with BS EN 16005 are located within the door operator to maintain back of door safety and protect pedestrians against crushing edges at the main closing edge.Fail-safe system (battery back-up) enables up to 30 minutes operation (subject to use) in the event of a mains failure. The fail safe system is automatically tested at least once every 24 hours.Fire alarm interface connection enables door leaves to fail safe to open in the event of an emergency. In compliance with BS EN 16005 door sets with a clear opening width of up to 2000 mm open by at least 80% within 3 seconds after activation by the activators in the escape direction (or within 5 seconds in the event of the loss of power).Operation:24 V DC motor with microprocessor controller which allows extensive options for opening width, electric locking, summer/ winter modes, exit only, manual control, speed of opening and the length of time the door is open. Power requirements:230 V single phase. A 13 A live neon-lit fused spur supply, protected by a 30 mA RCD must be provided prior to installation. In order to comply with BS EN 16005 the mains connection must be capable of disconnection to prevent unintentional and unauthorised reactivation.Clearances: - Width (maximum): Single sliding door: 1600 mm.Bi-parting sliding door: 3200 mm. - Height: Single sliding door: 2500 mm.Bi-parting sliding door: 2500 mm.Configuration (break out solutions only):The bi-parting sliding door system with break out is designed to provide convenient, barrier free access in day-to-day situations, while guaranteeing a safe exit for occupants and easy entry for emergency services in the event of a fire. In compliance with BS EN 16005 door leaves (or door set leaves and side screens) are capable of being broken out from any position in the direction of escape. The total force to release the break out function does not exceed 220 N. Rear door safety: Several options are available, subject to installation considerations. Please consult the manufacturer. The options available are;900 mm high, firmly secured, solid glazed barrier, in accordance with BSEN 16005.2.5 m high, fully glazed pocket screen complying with BS EN 16005.Security:A key turn manual hook lock (with steel insert in the leading edge for improved security and strength) is included as standard however there are a range of options available such as in head electric locks and multi point locking for added security. Integration with access control systems is also achievable. Please consult manufacturer.Control:D Bedix hard wired programming key pad (Incorporating digital display screen). Designed for installation in a central control panel. Configured for Automatic/ Manual/ Night/ Exit/ Open door operating modes.Portable Bedix wireless control unit designed to enable selection of operating modes (as per D Bedix) and configure parameters. Simple menu based controls. No fixed location required. Password protected.Kombi D Bedix, push button control (as standard D Bedix) incorporating additional security key to prevent unauthorized access.F Key: Multi user, compact programmable portable unit enabling restricted personnel access.Six position key switch. Single point door control but with NO fault identification.Operation:Additionally, the door allows for fitting of door position switches, fire or smoke alarm signals and voice message systems to assist partially sighted people and integrates with access control systems.Door movement guide:Surface mounted fixed point guide enhances efficiency of door movement.Recessed floor track:Helps further improve door security as well as improved weather sealing and resistance to strong winds and driving rain. Product literature:http://www.ribaproductselector.com/documentdetails.aspx?ci=03743&f=COL345157.pdf&pg=410BS476-22: 198710BS EN 1634-1: 200010ISO 9001: 20080CE approved0TUV NORD10DIN18650-1 and DIN 18650-2 (2005 and 2010)

The EI30 fire rated automatic sliding door system provides convenient, barrier-free access in day-to-day situations, while offering robust flame protection and easy entry for the emergency services in the event of a fire. The system can be used to divide rooms into compartments providing reliable fire protection along with a heat-shield for up to 30 minutes. If a fire alarm is activated, the automatic sliding fire-door can be opened manually like a conventional swing door in order to provide an emergency exit. Built-in closing mechanisms ensure that the door shuts again to provide a fire barrier once it has performed its emergency-exit function.

All equipment is installed by Automatic Door Suppliers Association (ADSA) accredited engineers.

More about EI30 Fire Rated Automatic Sliding Door System:
As standard - Options - Approvals

EI30 Fire Rated Automatic Sliding Door System
 Manufacturer:
Gilgen Door Systems UK Ltd.
  -Web:www.gilgendoorsystems.co.uk.
  -Tel:+44 (0)800 316 6994.
  -Product reference:
EI30 Fire Resistant Automatic Sliding Door System FAT.
 Door:
  -Configuration:
[Bi-parting sliding doors, no fixed panels].
[Bi-parting sliding doors, two fixed panels].
[Single sliding door, no fixed panels].
[Single sliding door, with panel].
 Clearance:
  -Height:
[ ______ ] - Insert requirements.
  -Width:
[ ______ ] - Insert requirements.
 Finish:
[Polyester powder coated RAL]. - Insert colour.
 Drive operation:
[Standard SLX].
[Standard SLX with booster].
[Heavy duty SLX V drive with dual motors].
 Infill:
[Solid construction].
[EI30, transparent fire resistant glass 15-17 mm].
[EI30, transparent fire resistant glass 23 mm].
 Control:
[D Bedix hard wired control incorporating digital display screen].
[F key].
[Kombi C Bedix push button control].
[Portable Bedix wireless unit].
[Six position key switch].
 Activation:
[Integration with access control systems].
[Manual push pad].
[Motion sensors].
[Touch-free push pad].
 Locking and security:
[ ______ ] - Installation specific; please consult manufacturer and insert requirements.
 Door movement guide:
[Recessed floor track]. - Not suitable if break out required.
[Surface mounted fixed point guide].
 Rear door safety:
[ ______ ] - Installation specific please consult manufacturer.


top ^

Guidance

for EI30 Fire Rated Automatic Sliding Door System

from Gilgen Door Systems UK Ltd

More about EI30 Fire Rated Automatic Sliding Door System: As standard - Options - Approvals

As standard

Door profile:

73 mm thick.

Door panel weight:

  • Standard SLX drive: 2 x 120 kg.
  • Standard SLX drive with booster: 2 x 150 kg.
  • SLX V drive with dual motors: 2 x 240 kg.

Drive system:

EI30 sliding door drive system integrates Bluetooth wireless control technology and a powerful, near silent drive into a slender profile. System components are connected via a can-bus, which not only guarantees smooth and reliable operation, but also facilitates constant communication with the processor to ensure optimum operational safety.

Safety:

  • Combined presence and activation sensing devices ensure door opening distances are in accordance with BS EN 16005, prevent doors closing on pedestrians within the threshold area and provide a signal to the door control system, thereby optimising pedestrian safety.
  • Rear edge sensors (electro sensitive protection equipment, ESPE) complying with BS EN 16005 are located within the door operator to maintain back of door safety and protect pedestrians against crushing edges at the main closing edge.
  • Fail-safe system (battery back-up) enables up to 30 minutes operation (subject to use) in the event of a mains failure. The fail safe system is automatically tested at least once every 24 hours.
  • Fire alarm interface connection enables door leaves to fail safe to open in the event of an emergency. In compliance with BS EN 16005 door sets with a clear opening width of up to 2000 mm open by at least 80% within 3 seconds after activation by the activators in the escape direction (or within 5 seconds in the event of the loss of power).

Operation:

24 V DC motor with microprocessor controller which allows extensive options for opening width, electric locking, summer/ winter modes, exit only, manual control, speed of opening and the length of time the door is open.

Power requirements:

230 V single phase. A 13 A live neon-lit fused spur supply, protected by a 30 mA RCD must be provided prior to installation. In order to comply with BS EN 16005 the mains connection must be capable of disconnection to prevent unintentional and unauthorised reactivation.

Options

Clearances:

- Width (maximum):

  • Single sliding door: 1600 mm.
  • Bi-parting sliding door: 3200 mm.

- Height:

  • Single sliding door: 2500 mm.
  • Bi-parting sliding door: 2500 mm.

Configuration (break out solutions only):

The bi-parting sliding door system with break out is designed to provide convenient, barrier free access in day-to-day situations, while guaranteeing a safe exit for occupants and easy entry for emergency services in the event of a fire. In compliance with BS EN 16005 door leaves (or door set leaves and side screens) are capable of being broken out from any position in the direction of escape. The total force to release the break out function does not exceed 220 N.

Rear door safety:

Several options are available, subject to installation considerations. Please consult the manufacturer. The options available are;

  • 900 mm high, firmly secured, solid glazed barrier, in accordance with BSEN 16005.
  • 2.5 m high, fully glazed pocket screen complying with BS EN 16005.

Security:

A key turn manual hook lock (with steel insert in the leading edge for improved security and strength) is included as standard however there are a range of options available such as in head electric locks and multi point locking for added security. Integration with access control systems is also achievable. Please consult manufacturer.

Control:

  • D Bedix hard wired programming key pad (Incorporating digital display screen). Designed for installation in a central control panel. Configured for Automatic/ Manual/ Night/ Exit/ Open door operating modes.
  • Portable Bedix wireless control unit designed to enable selection of operating modes (as per D Bedix) and configure parameters. Simple menu based controls. No fixed location required. Password protected.
  • Kombi D Bedix, push button control (as standard D Bedix) incorporating additional security key to prevent unauthorized access.
  • F Key: Multi user, compact programmable portable unit enabling restricted personnel access.
  • Six position key switch. Single point door control but with NO fault identification.

Operation:

Additionally, the door allows for fitting of door position switches, fire or smoke alarm signals and voice message systems to assist partially sighted people and integrates with access control systems.

Door movement guide:

Surface mounted fixed point guide enhances efficiency of door movement.

Recessed floor track:

Helps further improve door security as well as improved weather sealing and resistance to strong winds and driving rain.

Approvals

  • British Standards Institution: BS476-22: 1987. British Standards Institution
  • British Standards Institution: BS EN 1634-1: 2000. British Standards Institution
  • British Standards Institution: ISO 9001: 2008. British Standards Institution
  • CE approved .
  • TUV NORD .
  • British Standards Institution: DIN18650-1 and DIN 18650-2 (2005 and 2010). British Standards Institution

Further Information

Literature:


RIBA CPD

CPD information is available for Gilgen Door Systems UK Ltd from ribacpd.com.

RIBA Product Selector