A-Z Manufacturers (Dagard SAS) |  CAWS Index

View larger image of PST60 from Dagard SASPST60

The ceiling is designed for rooms which must be kept completely free of microbiological contamination.The non-combustible modular panels are 60 mm thick and manufactured from time-stable materials and no emitting particles.The ceiling provides smooth surfaces which are easy to clean, are air-tight and offer good insulation.A metallic profile is integrated into the grooves in order to hang the ceiling panels to the building structure.Components:Core: Aluminium honeycomb, link diameter 19 mm metal strip thickness 70 μ (ceiling panel). Alloy 3003 (EN 573 standard), with a rustproof treatment. Density: 28 kg/m³ (70 μ). Fire reaction: Non-combustible. Resistance to compression: Average value of 270 kPa.Adhesive: Bi-component polyurethane.Silicone sealant (quality-label SNJF; complies with FDA 21 CFR 175.105).Polymer MS caulk.Flexible sealant in closed cell reticulate polyethene adhesive strips (over the ceiling), density of 50 kg/m³.On request, the two facings can be manufactured from different materials on the inside and outside faces (aspect, colour and/ or thickness).Panel:- Thickness:60 mm.- Profile:Metallic profile for passage of cables.Acceptable span in ceiling:Without opening: 3 m (walkable), 5 m (non-walkable).With opening: 2–2.8 m (walkable), 2.4–4 m (non-walkable), depending on configuration. Consult literature for details.Loads taken into account for measurement: 60 daN/m² (panel weight included, panel on two supports) plus 150 daN (if accessible ceiling, concentrated load at any point of the ceiling).Small sections can be cut out (width: <600 mm) without compromising the safety of the ceiling.With nonstandard openings (width: >0.665 m and/ or area: >0.45 m²) it is necessary to use additional fastening joist.The ceiling is not a technical platform; for maintenance, it will support the passage of one person.Permissible loads:Varies depending on span and beam; consult literature for details.Technical characteristics:Weight: 10.7 kg/m² (two faces, 0.5 mm thick steel); 6.9 kg/m² (two faces, 0.67 mm aluminium).Fire reaction: Euroclass A2-s1,d0.0FM approval (standard 4880)Class 10UL approval (cable routing)Safety E471046

The ceiling is designed for rooms which must be kept completely free of microbiological contamination.

The non-combustible modular panels are 60 mm thick and manufactured from time-stable materials and no emitting particles.

The ceiling provides smooth surfaces which are easy to clean, are air-tight and offer good insulation.

A metallic profile is integrated into the grooves in order to hang the ceiling panels to the building structure.

Components:

  • Core: Aluminium honeycomb, link diameter 19 mm metal strip thickness 70 μ (ceiling panel). Alloy 3003 (EN 573 standard), with a rustproof treatment. Density: 28 kg/m³ (70 μ). Fire reaction: Non-combustible. Resistance to compression: Average value of 270 kPa.
  • Adhesive: Bi-component polyurethane.
  • Silicone sealant (quality-label SNJF; complies with FDA 21 CFR 175.105).
  • Polymer MS caulk.
  • Flexible sealant in closed cell reticulate polyethene adhesive strips (over the ceiling), density of 50 kg/m³.

On request, the two facings can be manufactured from different materials on the inside and outside faces (aspect, colour and/ or thickness).

More about PST60:
As standard - Approvals

PST60
 Manufacturer:
Dagard SAS.
  -Web:www.dagard.com/gb/.
  -Tel:+33 (0)555 824000.
  -Product reference:
PST60.
 Panel:
  -Width:
[350 mm].
[550 mm].
[1200 mm]. - 6000 mm maximum length only.
  -Length:
[4000 mm].
[6000 mm].
 Facing:
  -Thickness:
[0.5 mm]. - Polyester 25 μm lacquer finish only.
[0.6 mm]. - Standard.
[0.8 mm]. - Polyester 25 μm lacquer and stainless steel polished S4 finishes only.
  -Material:
[Smooth stainless steel sheet, 1.4307 (304 L) grade].
[Smooth stainless steel sheet, 1.4404 (316 L) grade].
[Steel sheet S280 GD, hot-dip galvanized Z225]. - 225 g/m² of zinc on the two faces or similar.
    Coating:
[Polished S4]. - Stainless steel only.
[Polyester 25 µm lacquer]. - Class in accordance with XP P 34-301: lIIa.
[Polyester lacquer and PET film of total thickness 55 µm]. - Class in accordance with XP P 34-301: Vc.
[PVC 150 µm antibacterial]. - Class in accordance with XP P 34-301: Vc.
[PVC and PET film of total thickness 130 µm]. - Stainless steel only.
[PVDF 35 µm lacquer]. - Class in accordance with XP P 34-301: lVb.
 Colour/ Finish:
Iceberg white (similar to RAL 9010).


top ^

Guidance

for PST60

from Dagard SAS

More about PST60: As standard - Approvals

As standard

Panel:

- Thickness:

60 mm.

- Profile:

Metallic profile for passage of cables.

Acceptable span in ceiling:

  • Without opening: 3 m (walkable), 5 m (non-walkable).
  • With opening: 2–2.8 m (walkable), 2.4–4 m (non-walkable), depending on configuration. Consult literature for details.
  • Loads taken into account for measurement: 60 daN/m² (panel weight included, panel on two supports) plus 150 daN (if accessible ceiling, concentrated load at any point of the ceiling).
  • Small sections can be cut out (width: <600 mm) without compromising the safety of the ceiling.
  • With nonstandard openings (width: >0.665 m and/ or area: >0.45 m²) it is necessary to use additional fastening joist.
  • The ceiling is not a technical platform; for maintenance, it will support the passage of one person.

Permissible loads:

Varies depending on span and beam; consult literature for details.

Technical characteristics:

  • Weight: 10.7 kg/m² (two faces, 0.5 mm thick steel); 6.9 kg/m² (two faces, 0.67 mm aluminium).
  • Fire reaction: Euroclass A2-s1,d0.

Approvals

  • FM approval (standard 4880): Class 1.
  • UL approval (cable routing): Safety E471046.

Further Information

Literature:

RIBA Product Selector

Additional information may be available for Dagard SAS from ribaproductselector.com.

Contacts:

www.dagard.com/gb/

T: +33 (0)555 824000

Drag work item to add to schedule

top ^

 
NBS Plus
NBS Building, online library, 18 December 2017