This NBS Plus page covers swing door operator, automatic sliding door, doorsets and automatic door operator

relating to clause 55 DOORSETS

in L20 Doors/ shutters/ hatches.

For more NBS Plus information from this company, see the Gilgen Door Systems UK Ltd overview page which includes a clause list and a product list.


Products from Gilgen Door Systems UK Ltd

Kaba Door Systems Ltd offer a design and specification service; consultation early in the design process is recommended.

Select to expand
Automatic door operators. (1)
Select to expand
Automatic sliding doors: (7)
Select to expand
Automatic Folding Doors (1)
 

View larger image of FD20 Swing Door Operator from Gilgen Door Systems UK LtdFD20 Swing Door Operator

An electro-mechanical swing door operator which provides quiet and smooth door operation. Suitable for internal and external doors in a wide variety of applications such as retail, hotel, office, airports, stations, hospitals, schools and industrial and commercial premises. Capable of reliably opening and closing doors even if exposed to wind speeds of up to 80 km/h (320 Pa).All equipment is designed to meet the rigorous safety requirements of BS EN 16005:2012, Building Regulations (E&W) Approved Document M, The Equality Act 2010 and BS 8300:2009. Installation is carried out by Automatic Door Suppliers Association (ADSA) accredited engineers.Door size:Height (maximum): 2500 mm.Width: 850–1600 mm.Door panel weight (maximum):250 kg.Operator size (h x w x d):85 x 690 x 120 mm.Drive system:Non–handed, in-swing or out-swing operator.Face mounted.Power to open, spring closing.Adjustable power, from low energy to full power.Safety monitoring with automatic stop/ reverse mechanism.Built in program selector keys located on side of operator.Safety features:In the event of power failure or fire alarm the door can be used manually.Fire alarm connections ensure door closes under full control from any position of operation.Finger safety guards and active infrared safety sensor to prevent contact with moving door leaves.Fire performance:Certified for use on fire doors, compliant to BS EN1634-1:2014: EI120 (120 minute fire rating) Timber door, timber frame with intumescent protection.EI60 (60 minute fire rating) Timber door, metal frame with intumescent protection.EI60 (60 minute fire rating) Metal door, metal frame.Operation:Electromechanical operation (no risk of oil leakage).Integrated LC- display to set relevant parameters.Active range: EN3–EN7.Wind load regulation.Push and Go function.In the event of power failure the door is closed in a controlled manner by means of the spring closerHold open time 1–60 seconds (adjustable).Maximum drive power consumption: 560 W.Motor Capacity: 100 W.Maximum opening angle: 105°.Maximum opening speed 40°/s.Maximum closing speed 40°/s.Power requirements:230 V single phase. A 13 A live neon-lit fused spur supply, protected by a 30 mA RCD must be provided prior to installation. In order to comply with BS EN 16005 the mains connection must be capable of disconnection to prevent unintentional and unauthorised reactivation.

An electro-mechanical swing door operator which provides quiet and smooth door operation. Suitable for internal and external doors in a wide variety of applications such as retail, hotel, office, airports, stations, hospitals, schools and industrial and commercial premises. Capable of reliably opening and closing doors even if exposed to wind speeds of up to 80 km/h (320 Pa).

All equipment is designed to meet the rigorous safety requirements of BS EN 16005:2012, Building Regulations (E&W) Approved Document M, The Equality Act 2010 and BS 8300:2009. Installation is carried out by Automatic Door Suppliers Association (ADSA) accredited engineers.

More about FD20 Swing Door Operator:
As standard - Further information.

PendingSWING DOOR OPERATOR:
 Manufacturer:
Gilgen Door Systems UK Ltd.
  -Web:www.gilgendoorsystems.co.uk.
  -Tel:+44 (0)800 316 6994.
  -Product reference:
FD20 Swing Door Operator.
 Door configuration:
[Double leaf].
[Single leaf].
 Finish:
[Natural anodized aluminium].
[Polished chromium steel].
 Accessories:
[None].
[Connection of electric locks/ locking mechanism].
[Contactless detection sensor].


top ^

Guidance

for FD20 Swing Door Operator

from Gilgen Door Systems UK Ltd

More about FD20 Swing Door Operator: As standard - Further information.

As standard

Door size:

  • Height (maximum): 2500 mm.
  • Width: 850–1600 mm.

Door panel weight (maximum):

250 kg.

Operator size (h x w x d):

85 x 690 x 120 mm.

Drive system:

  • Non–handed, in-swing or out-swing operator.
  • Face mounted.
  • Power to open, spring closing.
  • Adjustable power, from low energy to full power.
  • Safety monitoring with automatic stop/ reverse mechanism.
  • Built in program selector keys located on side of operator.

Safety features:

  • In the event of power failure or fire alarm the door can be used manually.
  • Fire alarm connections ensure door closes under full control from any position of operation.
  • Finger safety guards and active infrared safety sensor to prevent contact with moving door leaves.

Fire performance:

Certified for use on fire doors, compliant to BS EN1634-1:2014:

  • EI120 (120 minute fire rating) Timber door, timber frame with intumescent protection.
  • EI60 (60 minute fire rating) Timber door, metal frame with intumescent protection.
  • EI60 (60 minute fire rating) Metal door, metal frame.

Operation:

  • Electromechanical operation (no risk of oil leakage).
  • Integrated LC- display to set relevant parameters.
  • Active range: EN3–EN7.
  • Wind load regulation.
  • Push and Go function.
  • In the event of power failure the door is closed in a controlled manner by means of the spring closer
  • Hold open time 1–60 seconds (adjustable).
  • Maximum drive power consumption: 560 W.
  • Motor Capacity: 100 W.
  • Maximum opening angle: 105°.
  • Maximum opening speed 40°/s.
  • Maximum closing speed 40°/s.

Power requirements:

230 V single phase. A 13 A live neon-lit fused spur supply, protected by a 30 mA RCD must be provided prior to installation. In order to comply with BS EN 16005 the mains connection must be capable of disconnection to prevent unintentional and unauthorised reactivation.

Further Information

Literature:

RIBA CPD

CPD information is available for Gilgen Door Systems UK Ltd from ribacpd.com.

RIBA Product Selector

Additional information may be available for Gilgen Door Systems UK Ltd from ribaproductselector.com.

Contacts:

www.gilgendoorsystems.co.uk

info@gilgendoorsystems.co.uk

T: +44 (0)800 316 6994

F: +44 (0)800 316 6995

top ^

 

View larger image of EI30 Fire Rated Automatic Sliding Door System from Gilgen Door Systems UK LtdEI30 Fire Rated Automatic Sliding Door System

The EI30 fire rated automatic sliding door system provides convenient, barrier-free access in day-to-day situations, while offering robust flame protection and easy entry for the emergency services in the event of a fire. The system can be used to divide rooms into compartments providing reliable fire protection along with a heat-shield for up to 30 minutes. If a fire alarm is activated, the automatic sliding fire-door can be opened manually like a conventional swing door in order to provide an emergency exit. Built-in closing mechanisms ensure that the door shuts again to provide a fire barrier once it has performed its emergency-exit function.All equipment is installed by Automatic Door Suppliers Association (ADSA) accredited engineers.Door profile:73 mm thick.Door panel weight:Standard SLX drive: 2 x 120 kg.Standard SLX drive with booster: 2 x 150 kg.SLX V drive with dual motors: 2 x 240 kg.Drive system:EI30 sliding door drive system integrates Bluetooth wireless control technology and a powerful, near silent drive into a slender profile. System components are connected via a can-bus, which not only guarantees smooth and reliable operation, but also facilitates constant communication with the processor to ensure optimum operational safety.Safety:Combined presence and activation sensing devices ensure door opening distances are in accordance with BS EN 16005, prevent doors closing on pedestrians within the threshold area and provide a signal to the door control system, thereby optimising pedestrian safety.Rear edge sensors (electro sensitive protection equipment, ESPE) complying with BS EN 16005 are located within the door operator to maintain back of door safety and protect pedestrians against crushing edges at the main closing edge.Fail-safe system (battery back-up) enables up to 30 minutes operation (subject to use) in the event of a mains failure. The fail safe system is automatically tested at least once every 24 hours.Fire alarm interface connection enables door leaves to fail safe to open in the event of an emergency. In compliance with BS EN 16005 door sets with a clear opening width of up to 2000 mm open by at least 80% within 3 seconds after activation by the activators in the escape direction (or within 5 seconds in the event of the loss of power).Operation:24 V DC motor with microprocessor controller which allows extensive options for opening width, electric locking, summer/ winter modes, exit only, manual control, speed of opening and the length of time the door is open. Power requirements:230 V single phase. A 13 A live neon-lit fused spur supply, protected by a 30 mA RCD must be provided prior to installation. In order to comply with BS EN 16005 the mains connection must be capable of disconnection to prevent unintentional and unauthorised reactivation.Clearances: - Width (maximum): Single sliding door: 1600 mm.Bi-parting sliding door: 3200 mm. - Height: Single sliding door: 2500 mm.Bi-parting sliding door: 2500 mm.Configuration (break out solutions only):The bi-parting sliding door system with break out is designed to provide convenient, barrier free access in day-to-day situations, while guaranteeing a safe exit for occupants and easy entry for emergency services in the event of a fire. In compliance with BS EN 16005 door leaves (or door set leaves and side screens) are capable of being broken out from any position in the direction of escape. The total force to release the break out function does not exceed 220 N. Rear door safety: Several options are available, subject to installation considerations. Please consult the manufacturer. The options available are;900 mm high, firmly secured, solid glazed barrier, in accordance with BSEN 16005.2.5 m high, fully glazed pocket screen complying with BS EN 16005.Security:A key turn manual hook lock (with steel insert in the leading edge for improved security and strength) is included as standard however there are a range of options available such as in head electric locks and multi point locking for added security. Integration with access control systems is also achievable. Please consult manufacturer.Control:D Bedix hard wired programming key pad (Incorporating digital display screen). Designed for installation in a central control panel. Configured for Automatic/ Manual/ Night/ Exit/ Open door operating modes.Portable Bedix wireless control unit designed to enable selection of operating modes (as per D Bedix) and configure parameters. Simple menu based controls. No fixed location required. Password protected.Kombi D Bedix, push button control (as standard D Bedix) incorporating additional security key to prevent unauthorized access.F Key: Multi user, compact programmable portable unit enabling restricted personnel access.Six position key switch. Single point door control but with NO fault identification.Operation:Additionally, the door allows for fitting of door position switches, fire or smoke alarm signals and voice message systems to assist partially sighted people and integrates with access control systems.Door movement guide:Surface mounted fixed point guide enhances efficiency of door movement.Recessed floor track:Helps further improve door security as well as improved weather sealing and resistance to strong winds and driving rain. Product literature:http://www.ribaproductselector.com/documentdetails.aspx?ci=03743&f=COL345157.pdf&pg=410BS476-22: 198710BS EN 1634-1: 200010ISO 9001: 20080CE approved0TUV NORD10DIN18650-1 and DIN 18650-2 (2005 and 2010)

The EI30 fire rated automatic sliding door system provides convenient, barrier-free access in day-to-day situations, while offering robust flame protection and easy entry for the emergency services in the event of a fire. The system can be used to divide rooms into compartments providing reliable fire protection along with a heat-shield for up to 30 minutes. If a fire alarm is activated, the automatic sliding fire-door can be opened manually like a conventional swing door in order to provide an emergency exit. Built-in closing mechanisms ensure that the door shuts again to provide a fire barrier once it has performed its emergency-exit function.

All equipment is installed by Automatic Door Suppliers Association (ADSA) accredited engineers.

More about EI30 Fire Rated Automatic Sliding Door System:
As standard - Options - Approvals - Further information.

PendingAUTOMATIC SLIDING DOOR:
 Manufacturer:
Gilgen Door Systems UK Ltd.
  -Web:www.gilgendoorsystems.co.uk.
  -Tel:+44 (0)800 316 6994.
  -Product reference:
EI30 Fire Resistant Automatic Sliding Door System FAT.
 Door:
  -Configuration:
[Bi-parting sliding doors, no fixed panels].
[Bi-parting sliding doors, two fixed panels].
[Single sliding door, no fixed panels].
 Clearance:
  -Height:
[ ______ ] - Insert requirements.
  -Width:
[ ______ ] - Insert requirements.
 Finish:
[Polyester powder coated RAL]. - Insert colour.
 Drive operation:
[Standard SLX].
[Standard SLX with booster].
[Heavy duty SLX V drive with dual motors].
 Infill:
[Solid construction].
[EI30, transparent fire resistant glass 15-17 mm].
[EI30, transparent fire resistant glass 23 mm].
 Control:
[D Bedix hard wired control incorporating digital display screen].
[F key].
[Kombi C Bedix push button control].
 Activation:
[Integration with access control systems].
[Manual push pad].
[Motion sensors].
 Locking and security:
[ ______ ] - Installation specific; please consult manufacturer and insert requirements.
 Door movement guide:
[Recessed floor track]. - Not suitable if break out required.
[Surface mounted fixed point guide].
 Rear door safety:
[ ______ ] - Installation specific please consult manufacturer.


top ^

Guidance

for EI30 Fire Rated Automatic Sliding Door System

from Gilgen Door Systems UK Ltd

More about EI30 Fire Rated Automatic Sliding Door System: As standard - Options - Approvals - Further information.

As standard

Door profile:

73 mm thick.

Door panel weight:

  • Standard SLX drive: 2 x 120 kg.
  • Standard SLX drive with booster: 2 x 150 kg.
  • SLX V drive with dual motors: 2 x 240 kg.

Drive system:

EI30 sliding door drive system integrates Bluetooth wireless control technology and a powerful, near silent drive into a slender profile. System components are connected via a can-bus, which not only guarantees smooth and reliable operation, but also facilitates constant communication with the processor to ensure optimum operational safety.

Safety:

  • Combined presence and activation sensing devices ensure door opening distances are in accordance with BS EN 16005, prevent doors closing on pedestrians within the threshold area and provide a signal to the door control system, thereby optimising pedestrian safety.
  • Rear edge sensors (electro sensitive protection equipment, ESPE) complying with BS EN 16005 are located within the door operator to maintain back of door safety and protect pedestrians against crushing edges at the main closing edge.
  • Fail-safe system (battery back-up) enables up to 30 minutes operation (subject to use) in the event of a mains failure. The fail safe system is automatically tested at least once every 24 hours.
  • Fire alarm interface connection enables door leaves to fail safe to open in the event of an emergency. In compliance with BS EN 16005 door sets with a clear opening width of up to 2000 mm open by at least 80% within 3 seconds after activation by the activators in the escape direction (or within 5 seconds in the event of the loss of power).

Operation:

24 V DC motor with microprocessor controller which allows extensive options for opening width, electric locking, summer/ winter modes, exit only, manual control, speed of opening and the length of time the door is open.

Power requirements:

230 V single phase. A 13 A live neon-lit fused spur supply, protected by a 30 mA RCD must be provided prior to installation. In order to comply with BS EN 16005 the mains connection must be capable of disconnection to prevent unintentional and unauthorised reactivation.

Options

Clearances:

- Width (maximum):

  • Single sliding door: 1600 mm.
  • Bi-parting sliding door: 3200 mm.

- Height:

  • Single sliding door: 2500 mm.
  • Bi-parting sliding door: 2500 mm.

Configuration (break out solutions only):

The bi-parting sliding door system with break out is designed to provide convenient, barrier free access in day-to-day situations, while guaranteeing a safe exit for occupants and easy entry for emergency services in the event of a fire. In compliance with BS EN 16005 door leaves (or door set leaves and side screens) are capable of being broken out from any position in the direction of escape. The total force to release the break out function does not exceed 220 N.

Rear door safety:

Several options are available, subject to installation considerations. Please consult the manufacturer. The options available are;

  • 900 mm high, firmly secured, solid glazed barrier, in accordance with BSEN 16005.
  • 2.5 m high, fully glazed pocket screen complying with BS EN 16005.

Security:

A key turn manual hook lock (with steel insert in the leading edge for improved security and strength) is included as standard however there are a range of options available such as in head electric locks and multi point locking for added security. Integration with access control systems is also achievable. Please consult manufacturer.

Control:

  • D Bedix hard wired programming key pad (Incorporating digital display screen). Designed for installation in a central control panel. Configured for Automatic/ Manual/ Night/ Exit/ Open door operating modes.
  • Portable Bedix wireless control unit designed to enable selection of operating modes (as per D Bedix) and configure parameters. Simple menu based controls. No fixed location required. Password protected.
  • Kombi D Bedix, push button control (as standard D Bedix) incorporating additional security key to prevent unauthorized access.
  • F Key: Multi user, compact programmable portable unit enabling restricted personnel access.
  • Six position key switch. Single point door control but with NO fault identification.

Operation:

Additionally, the door allows for fitting of door position switches, fire or smoke alarm signals and voice message systems to assist partially sighted people and integrates with access control systems.

Door movement guide:

Surface mounted fixed point guide enhances efficiency of door movement.

Recessed floor track:

Helps further improve door security as well as improved weather sealing and resistance to strong winds and driving rain.

Approvals

  • British Standards Institution: BS476-22: 1987. British Standards Institution
  • British Standards Institution: BS EN 1634-1: 2000. British Standards Institution
  • British Standards Institution: ISO 9001: 2008. British Standards Institution
  • CE approved .
  • TUV NORD .
  • British Standards Institution: DIN18650-1 and DIN 18650-2 (2005 and 2010). British Standards Institution

Further Information

Literature:


RIBA CPD

CPD information is available for Gilgen Door Systems UK Ltd from ribacpd.com.

RIBA Product Selector

Additional information may be available for Gilgen Door Systems UK Ltd from ribaproductselector.com.

Contacts:

www.gilgendoorsystems.co.uk

info@gilgendoorsystems.co.uk

T: +44 (0)800 316 6994

F: +44 (0)800 316 6995

top ^

 

View larger image of PST Insulated Automatic Sliding Door System from Gilgen Door Systems UK LtdPST Insulated Automatic Sliding Door System

Tested in accordance with EN 16361/ EN 14351-1 the PST automatic door system consists of thermally insulated Gilgen PST door profiles matched with Gilgen’s SLX-M operator. This combination delivers both an energy efficient and visually appealing solution with low U-values (1.1–1.8 W/m²k), low air permeability, high wind load capacity and high resistance to driving rain.The slimline PST door profile delivers a robust thermal barrier combined with a low visible profile suitable for high volume, heavy duty, retail trade, hotels, offices, transport terminals, hospitals, schools, colleges, garden centres and leisure. All equipment is designed to meet the rigorous safety requirements of BS EN 16005, Building Regulations (E & W) Part M and The Equality Act 2010, BS 8300. Furthermore, equipment is installed by Automatic Door Suppliers Association (ADSA) accredited engineers.Drive system:SLX-M sliding door drive system integrates Bluetooth wireless control technology and a powerful, near silent drive into a very slender in profile. System components are connected via a can-bus, which not only guarantees smooth and reliable operation, but also facilitates constant communication with the processor to ensure optimum operational safety.Safety:Combined presence and activation sensing devices ensure door opening distances are in accordance with BS EN 16005, prevent doors closing on pedestrians within the threshold area and provide a signal to the door control system, thereby optimizing pedestrian safety.Rear edge sensors (electro sensitive protection equipment, ESPE) complying with BS EN 16005 are located within the door operator to maintain back of door safety and protect pedestrians against crushing edges at the main closing edge.Fail-safe system (battery back-up) enables up to 30 minutes operation (subject to use) in the event of a mains failure. The fail safe system is automatically tested at least once every 24 hours.Fire alarm interface connection enables door leaves to fail safe to open in the event of an emergency. In compliance with BS EN 16005 door sets with a clear opening width of up to 2000 mm open by at least 80% within three seconds after activation by the activators in the escape direction (or within five seconds in the event of the loss of power).Operation:24 V DC motor with microprocessor controller which allows extensive options for opening width, electric locking, summer/ winter modes, exit only, manual control, speed of opening and the length of time the door is open. Door weight:Single sliding doors: 1 x 150 kg.Bi-parting doors: 2 x 250 kg.Power requirements:230 V single phase. A 13 A live neon-lit fused spur supply, protected by a 30 mA. In order to comply with BS EN 16005 the mains connection must be capable of disconnection to prevent unintentional and unauthorised reactivation.Rear door safety:Several options are available, subject to installation considerations. Please consult the manufacturer. The options available are:900 mm high, firmly secured, solid glazed barrier, in accordance with BSEN 16005.2.5 m high, fully glazed pocket screen complying with BS EN 16005.Control:D Bedix hard wired programming key pad (incorporating digital display screen) designed for installation in a central control panel. Configured for automatic/ manual/ night/ exit/ open door operating modes.Portable Bedix wireless control unit designed to enable selection of operating modes (as per D Bedix) and configure parameters. Simple menu based controls. No fixed location required. Password protected.Kombi D Bedix, push button control (as standard D Bedix) incorporating additional security key to prevent unauthorized access.F Key: Multi user, compact programmable portable unit enabling restricted personnel access.Six position key switch. Single point door control but with NO fault identification.Operation:Additionally, the door allows for fitting of door position switches, fire or smoke alarm signals, voice message systems to assist partially sighted people and integrates with access control systems.Door movement guide:Surface mounted fixed point guide enhances efficiency of door movement.Recessed floor track:Helps further improve door security as well as improved weather sealing and resistance to strong winds and driving rain.0CEApproved0TUVApproved10Air permeability Class 2 (PPD2) in accordance with EN 1220710Class 5A water tightness in accordance with EN 1220810Wind Load Capacity PPD 800A, PPD 800B, PPD 700C

Tested in accordance with EN 16361/ EN 14351-1 the PST automatic door system consists of thermally insulated Gilgen PST door profiles matched with Gilgen’s SLX-M operator. This combination delivers both an energy efficient and visually appealing solution with low U-values (1.1–1.8 W/m²k), low air permeability, high wind load capacity and high resistance to driving rain.

The slimline PST door profile delivers a robust thermal barrier combined with a low visible profile suitable for high volume, heavy duty, retail trade, hotels, offices, transport terminals, hospitals, schools, colleges, garden centres and leisure. All equipment is designed to meet the rigorous safety requirements of BS EN 16005, Building Regulations (E & W) Part M and The Equality Act 2010, BS 8300. Furthermore, equipment is installed by Automatic Door Suppliers Association (ADSA) accredited engineers.

More about PST Insulated Automatic Sliding Door System:
As standard - Options - Approvals - Further information.

PendingAUTOMATIC SLIDING DOOR:
 Manufacturer:
Gilgen Door Systems UK Ltd.
  -Web:www.gilgendoorsystems.co.uk.
  -Tel:+44 (0)800 316 6994.
  -Product reference:
PST Insulated Automatic Sliding Door System.
 Door:
  -Configuration:
[Bi parting no fixed side panels].
[Bi parting two fixed side panels].
[Bi-parting, two fixed panels and fan light].
  -Clearance width:
[ ______ ] - 700–1500 mm (single sliding); 800–3000 mm (bi-parting).
  -Height:
[ ______ ] - 2100–3000 mm; insert requirements.
 Finish:
[Polyester powder coated, RAL]. - Insert colour requirements.
 Glazing:
[ ______ ] - Insulating glass, double glazing 24–28 mm thickness. Triple glazing 31–38 mm. Installation specific; please consult manufacturer and insert requirements.
 Control:
[D Bedix hard wired control unit].
[F Key].
[Kombi D Bedix].
 Activation:
[Integration with access control systems].
[Manual push pad].
[Motion sensors].
 Locking and security:
[Multipoint].
[Standard locking built into drive mechanism].
 Door movement guide:
[Recessed floor track].
[Surface mounted fixed point guide].
 Rear door safety:
[ ______ ] - Installation specific please consult manufacturer.


top ^

Guidance

for PST Insulated Automatic Sliding Door System

from Gilgen Door Systems UK Ltd

More about PST Insulated Automatic Sliding Door System: As standard - Options - Approvals - Further information.

As standard

Drive system:

SLX-M sliding door drive system integrates Bluetooth wireless control technology and a powerful, near silent drive into a very slender in profile. System components are connected via a can-bus, which not only guarantees smooth and reliable operation, but also facilitates constant communication with the processor to ensure optimum operational safety.

Safety:

  • Combined presence and activation sensing devices ensure door opening distances are in accordance with BS EN 16005, prevent doors closing on pedestrians within the threshold area and provide a signal to the door control system, thereby optimizing pedestrian safety.
  • Rear edge sensors (electro sensitive protection equipment, ESPE) complying with BS EN 16005 are located within the door operator to maintain back of door safety and protect pedestrians against crushing edges at the main closing edge.
  • Fail-safe system (battery back-up) enables up to 30 minutes operation (subject to use) in the event of a mains failure. The fail safe system is automatically tested at least once every 24 hours.
  • Fire alarm interface connection enables door leaves to fail safe to open in the event of an emergency. In compliance with BS EN 16005 door sets with a clear opening width of up to 2000 mm open by at least 80% within three seconds after activation by the activators in the escape direction (or within five seconds in the event of the loss of power).

Operation:

24 V DC motor with microprocessor controller which allows extensive options for opening width, electric locking, summer/ winter modes, exit only, manual control, speed of opening and the length of time the door is open.

Door weight:

  • Single sliding doors: 1 x 150 kg.
  • Bi-parting doors: 2 x 250 kg.

Power requirements:

230 V single phase. A 13 A live neon-lit fused spur supply, protected by a 30 mA. In order to comply with BS EN 16005 the mains connection must be capable of disconnection to prevent unintentional and unauthorised reactivation.

Options

Rear door safety:

Several options are available, subject to installation considerations. Please consult the manufacturer. The options available are:

  • 900 mm high, firmly secured, solid glazed barrier, in accordance with BSEN 16005.
  • 2.5 m high, fully glazed pocket screen complying with BS EN 16005.

Control:

  • D Bedix hard wired programming key pad (incorporating digital display screen) designed for installation in a central control panel. Configured for automatic/ manual/ night/ exit/ open door operating modes.
  • Portable Bedix wireless control unit designed to enable selection of operating modes (as per D Bedix) and configure parameters. Simple menu based controls. No fixed location required. Password protected.
  • Kombi D Bedix, push button control (as standard D Bedix) incorporating additional security key to prevent unauthorized access.
  • F Key: Multi user, compact programmable portable unit enabling restricted personnel access.
  • Six position key switch. Single point door control but with NO fault identification.

Operation:

Additionally, the door allows for fitting of door position switches, fire or smoke alarm signals, voice message systems to assist partially sighted people and integrates with access control systems.

Door movement guide:

Surface mounted fixed point guide enhances efficiency of door movement.

Recessed floor track:

Helps further improve door security as well as improved weather sealing and resistance to strong winds and driving rain.

Approvals

  • CE: Approved.
  • TUV: Approved.
  • British Standards Institution: Air permeability Class 2 (PPD2) in accordance with EN 12207. British Standards Institution
  • British Standards Institution: Class 5A water tightness in accordance with EN 12208. British Standards Institution
  • British Standards Institution: Wind Load Capacity PPD 800A, PPD 800B, PPD 700C. British Standards Institution

Further Information

Literature:

RIBA CPD

CPD information is available for Gilgen Door Systems UK Ltd from ribacpd.com.

RIBA Product Selector

Additional information may be available for Gilgen Door Systems UK Ltd from ribaproductselector.com.

Contacts:

www.gilgendoorsystems.co.uk

info@gilgendoorsystems.co.uk

T: +44 (0)800 316 6994

F: +44 (0)800 316 6995

top ^

 

View larger image of RC2/3 Automatic Sliding Door System (Burglar Resistance) from Gilgen Door Systems UK LtdRC2/3 Automatic Sliding Door System (Burglar Resistance)

RC2/3 automatic doors are suitable for applications with a higher threat of break-in or criminal attack such as banks, jewellers shops, electrical retailers, museums and offices. The reinforced door profiles incorporate a multi point locking mechanism approved to EN 1628 (static tests), EN 1629 (dynamic tests) and EN 1630 (manual burglar test) thereby achieving overall security rating of RC2 or RC3.RC3 has also been assessed to conform to the security requirement of PAS24:2012.Thanks to their slim line looks, RC2/3 automatic doors are similar in appearance to standard automatic doors offering a solution that is suitable for design conscious environments. Designed to satisfy BS EN 16005:2012. Gilgen SLX –M sliding door operators are tested for 1 million cycles, providing proven reliability. Compliance with other notable UK standards such as Part M & Part B of the building regulations, The Equality Act and BS 8300:2009 is also achieved.Drive system:RC2/3 SLX-M sliding door drive system integrates Bluetooth wireless control technology and a powerful, near silent drive into a very slender in profile. System components are connected via a can-bus, which not only guarantees smooth and reliable operation, but also facilitates constant communication with the processor to ensure optimum operational safety.Safety:Combined presence and activation sensing devices ensure door opening distances are in accordance with BS EN 16005, prevent doors closing on pedestrians within the threshold area and provide a signal to the door control system, thereby optimising pedestrian safety.Rear edge sensors (electro sensitive protection equipment, ESPE) complying with BS EN 16005 are located within the door operator to maintain back of door safety and protect pedestrians against crushing edges at the main closing edge.Fail-safe system (battery back-up) enables up to 30 minutes operation (subject to use) in the event of a mains failure. The fail safe system is automatically tested at least once every 24 hours.Fire alarm interface connection enables door leaves to fail safe to open in the event of an emergency. In compliance with BS EN 16005 door sets with a clear opening width of up to 2000 mm open by at least 80% within 3 seconds after activation by the activators in the escape direction (or within 5 seconds in the event of the loss of power.)Operation:24V DC motor with microprocessor controller which allows extensive options for opening width, electric locking, summer/ winter modes, exit only, manual control, speed of opening and the length of time the door is open. Security:A choice of either automatic or manual multipoint locking (integrated into the door leaf) is available please consult the manufacturer. Door weight:Single sliding doors: 1 x 150 kg.Bi-parting doors: 2 x 250 kg.Power requirements:230 V single phase. A 13 A live neon-lit fused spur supply, protected by a 30 mA RCD must be provided prior to installation. In order to comply with BS EN 16005 the mains connection must be capable of disconnection to prevent unintentional and unauthorised reactivation.Height:Single sliding, RC2: 2000–3330 mm.Single sliding, RC3: 2000–2640 mm.Bi-parting, RC2: 2000–3330 mm.Bi-parting, RC3: 2000–2640 mm.Rear door safety:Several options are available, subject to installation considerations. Please consult the manufacturer. The options available are;900 mm high, firmly secured, solid glazed barrier, in accordance with BSEN 16005.2.5 m high, fully glazed pocket screen complying with BS EN 16005.Control:D Bedix hard wired programming key pad (incorporating digital display screen) designed for installation in a central control panel. Configured for automatic/ manual/ night/ exit/ open door operating modes.Portable Bedix wireless control unit designed to enable selection of operating modes (as per D Bedix) and configure parameters. Simple menu based controls. No fixed location required. Password protected.Kombi D Bedix, push button control (as standard D Bedix) incorporating additional security key to prevent unauthorized access.F Key: Multi user, compact programmable portable unit enabling restricted personnel access.Six position key switch. Single point door control but with NO fault identification.Operation:Additionally, the door allows for fitting of door position switches, fire or smoke alarm signals, voice message systems to assist partially sighted people and integrates with access control systems.Door movement guide:Surface mounted fixed point guide enhances efficiency of door movement.Recessed floor track: Helps further improve door security as well as improved weather sealing and resistance to strong winds and driving rain. Product literature:http://www.ribaproductselector.com/documentdetails.aspx?ci=03743&f=COL489625.pdf&pg=10CE approval0TUV10RC2 and RC3 in accordance with EN 1627 to EN 1630 (2011)0Exova WarringtonFireAssessed to conform to the security requirements of PAS24:2012

RC2/3 automatic doors are suitable for applications with a higher threat of break-in or criminal attack such as banks, jewellers shops, electrical retailers, museums and offices. The reinforced door profiles incorporate a multi point locking mechanism approved to EN 1628 (static tests), EN 1629 (dynamic tests) and EN 1630 (manual burglar test) thereby achieving overall security rating of RC2 or RC3.

RC3 has also been assessed to conform to the security requirement of PAS24:2012.

Thanks to their slim line looks, RC2/3 automatic doors are similar in appearance to standard automatic doors offering a solution that is suitable for design conscious environments. Designed to satisfy BS EN 16005:2012. Gilgen SLX –M sliding door operators are tested for 1 million cycles, providing proven reliability. Compliance with other notable UK standards such as Part M & Part B of the building regulations, The Equality Act and BS 8300:2009 is also achieved.

More about RC2/3 Automatic Sliding Door System (Burglar Resistance):
As standard - Options - Approvals - Further information.

PendingDOORSETS:
 Manufacturer:
Gilgen Door Systems UK Ltd.
  -Web:www.gilgendoorsystems.co.uk.
  -Tel:+44 (0)800 316 6994.
  -Product reference:
RC2/3 Automatic Sliding Door System.
 Door :
  -Configuration:
[Single sliding WITHOUT side panel].
[Bi parting NO fixed side panels].
[Bi parting TWO fixed side panels].
  -Clearance width:
[ ______ ] - 700–1650 mm (single sliding); 800–3000 mm (bi-parting).
  -Height:
[ ______ ] - Insert requirements from 'Options' below.
 Finish:
[Polyester powder coated, RAL]. - Insert colour requirements.
[Silver anodised].
 Glazing:
[Glazed fan light option]. - Bi-parting only, consult manufacturer.
[P4A (EN356) high security glass (RC2)].
[P5A (EN356) high security glass (RC3)].
 Control:
[D Bedix hard wired control unit].
[F Key].
[Kombi D Bedix].
 Security locking:
[Manual].
[Automatic].
 Activation:
[Integration with access control systems].
[Manual push pad].
[Motion sensors].
 Door movement guide:
[Recessed floor track].
[Surface mounted fixed point guide].
 Rear door safety:
[ ______ ] - Installation specific please consult manufacturer.


top ^

Guidance

for RC2/3 Automatic Sliding Door System (Burglar Resistance)

from Gilgen Door Systems UK Ltd

More about RC2/3 Automatic Sliding Door System (Burglar Resistance): As standard - Options - Approvals - Further information.

As standard

Drive system:

RC2/3 SLX-M sliding door drive system integrates Bluetooth wireless control technology and a powerful, near silent drive into a very slender in profile. System components are connected via a can-bus, which not only guarantees smooth and reliable operation, but also facilitates constant communication with the processor to ensure optimum operational safety.

Safety:

  • Combined presence and activation sensing devices ensure door opening distances are in accordance with BS EN 16005, prevent doors closing on pedestrians within the threshold area and provide a signal to the door control system, thereby optimising pedestrian safety.
  • Rear edge sensors (electro sensitive protection equipment, ESPE) complying with BS EN 16005 are located within the door operator to maintain back of door safety and protect pedestrians against crushing edges at the main closing edge.
  • Fail-safe system (battery back-up) enables up to 30 minutes operation (subject to use) in the event of a mains failure. The fail safe system is automatically tested at least once every 24 hours.
  • Fire alarm interface connection enables door leaves to fail safe to open in the event of an emergency. In compliance with BS EN 16005 door sets with a clear opening width of up to 2000 mm open by at least 80% within 3 seconds after activation by the activators in the escape direction (or within 5 seconds in the event of the loss of power.)

Operation:

24V DC motor with microprocessor controller which allows extensive options for opening width, electric locking, summer/ winter modes, exit only, manual control, speed of opening and the length of time the door is open.

Security:

A choice of either automatic or manual multipoint locking (integrated into the door leaf) is available please consult the manufacturer.

Door weight:

  • Single sliding doors: 1 x 150 kg.
  • Bi-parting doors: 2 x 250 kg.

Power requirements:

230 V single phase. A 13 A live neon-lit fused spur supply, protected by a 30 mA RCD must be provided prior to installation. In order to comply with BS EN 16005 the mains connection must be capable of disconnection to prevent unintentional and unauthorised reactivation.

Options

Height:

  • Single sliding, RC2: 2000–3330 mm.
  • Single sliding, RC3: 2000–2640 mm.
  • Bi-parting, RC2: 2000–3330 mm.
  • Bi-parting, RC3: 2000–2640 mm.

Rear door safety:

Several options are available, subject to installation considerations. Please consult the manufacturer. The options available are;

  • 900 mm high, firmly secured, solid glazed barrier, in accordance with BSEN 16005.
  • 2.5 m high, fully glazed pocket screen complying with BS EN 16005.

Control:

  • D Bedix hard wired programming key pad (incorporating digital display screen) designed for installation in a central control panel. Configured for automatic/ manual/ night/ exit/ open door operating modes.
  • Portable Bedix wireless control unit designed to enable selection of operating modes (as per D Bedix) and configure parameters. Simple menu based controls. No fixed location required. Password protected.
  • Kombi D Bedix, push button control (as standard D Bedix) incorporating additional security key to prevent unauthorized access.
  • F Key: Multi user, compact programmable portable unit enabling restricted personnel access.
  • Six position key switch. Single point door control but with NO fault identification.

Operation:

Additionally, the door allows for fitting of door position switches, fire or smoke alarm signals, voice message systems to assist partially sighted people and integrates with access control systems.

Door movement guide:

Surface mounted fixed point guide enhances efficiency of door movement.

Recessed floor track:

Helps further improve door security as well as improved weather sealing and resistance to strong winds and driving rain.

Approvals

  • CE approval .
  • TUV .
  • British Standards Institution: RC2 and RC3 in accordance with EN 1627 to EN 1630 (2011). British Standards Institution
  • Exova WarringtonFire: Assessed to conform to the security requirements of PAS24:2012 .

Further Information

Literature:


RIBA CPD

CPD information is available for Gilgen Door Systems UK Ltd from ribacpd.com.

RIBA Product Selector

Additional information may be available for Gilgen Door Systems UK Ltd from ribaproductselector.com.

Contacts:

www.gilgendoorsystems.co.uk

info@gilgendoorsystems.co.uk

T: +44 (0)800 316 6994

F: +44 (0)800 316 6995

top ^

 

View larger image of SLX/D Hermetically Sealed Sliding Door from Gilgen Door Systems UK LtdSLX/D Hermetically Sealed Automatic Sliding Door

Tested for 1 million cycles SLX sliding door operators offer proven reliability as well as the integration of a number of technological advancements such as CanBus technology for enhanced operational safety and blue tooth wireless technology for easier access and control. The SLX/D with its unique patented pivot mechanism is the ideal choice where air tight door and hands free access are a priority for guaranteed optimum hygiene or sound proofing. It is particularly suitable for doors in hospitals, operating rooms, laboratories, music rooms, pharmaceutical and food industries.All equipment is installed by Automatic Door Suppliers Association (ADSA) accredited engineers.Drive system:SLX Sliding door drive unit with pivoting mechanism that enables the sliding wing to be simultaneously lowered and pressed against the door frame during the closing motion.Integrates Bluetooth wireless control technology and powerful, near silent drive into a very slender profile. System components are connected via a CANbus, which not only guarantees smooth and reliable operation, but also facilitates constant communication with the processor to ensure optimum operational safety.Safety:Combined presence and activation sensing devices ensure door opening distances are in accordance with BS EN 16005, prevent doors closing on pedestrians within the threshold area and provide a signal to the door control system, thereby optimising pedestrian safety.Rear edge sensors (electro sensitive protection equipment, ESPE) complying with BS EN 16005 are located within the door operator to maintain back of door safety and protect pedestrians against crushing edges at the main closing edge.Fail-safe system (battery back-up) enables up to 30 minutes operation (subject to use) in the event of a mains failure. The fail safe system is automatically tested at least once every 24 hours.Fire alarm interface connection enables door leaves to fail safe to open in the event of an emergency. In compliance with BS EN 16005 door sets with a clear opening width of up to 2000 mm open by at least 80% within 3 seconds after activation by the activators in the escape direction (or within 5 seconds in the event of the loss of power.)Water resistance:IP20 rating.Operation:24 V DC motor with microprocessor controller which allows extensive options for opening width, electric locking, summer/ winter modes, exit only, manual control, speed of opening and the length of time the door is open. Power requirements:230 V single phase. A 13 A live neon-lit fused spur supply, protected by a 30 mA RCD must be provided prior to installation. In order to comply with BS EN 16005 the mains connection must be capable of disconnection to prevent unintentional and unauthorised reactivation.Door panel weight (maximum):120 kg.Control:Portable Bedix wireless control unit: Designed to enable selection of operating modes and configure parameters. Simple menu based controls. No fixed location required. Password protected.D-Bedix hard wired programming key pad with digital display. Designed for installing a central control panel. Configured or Automatic – Night – Exit – Open door operating modes.F Key: Each unit can be programmed to restrict access to areas which normally need to be kept locked.Operation:Additionally, the door allows for fitting of door position switches, fire or smoke alarm signals and voice message systems to assist partially sighted people and integrates with access control systems.X-Ray shielding:With lead insert and special window.Product literature:http://www.ribaproductselector.com/documentdetails.aspx?ci=03743&f=COL264757.pdf&pg=10CE approval0TUV NORD10DIN18650-1 and DIN 18650-2 (2005 and 2010)10EN 12207 Class 2 Air permeability10ISO 9001: 2008

Tested for 1 million cycles SLX sliding door operators offer proven reliability as well as the integration of a number of technological advancements such as CanBus technology for enhanced operational safety and blue tooth wireless technology for easier access and control.

The SLX/D with its unique patented pivot mechanism is the ideal choice where air tight door and hands free access are a priority for guaranteed optimum hygiene or sound proofing. It is particularly suitable for doors in hospitals, operating rooms, laboratories, music rooms, pharmaceutical and food industries.

All equipment is installed by Automatic Door Suppliers Association (ADSA) accredited engineers.

More about SLX/D Hermetically Sealed Automatic Sliding Door:
As standard - Options - Approvals - Further information.

PendingAUTOMATIC SLIDING DOOR:
 Manufacturer:
Gilgen Door Systems UK Ltd.
  -Web:www.gilgendoorsystems.co.uk.
  -Tel:+44 (0)800 316 6994.
  -Product reference:
SLX/D Hermetically Sealed automatic Sliding Door.
 Door:
  -Configuration:
[Single Slide left].
[Single Slide right].
  -Clearance width:
[ ______ ] - 800–2000 mm; insert requirements.
  -Height:
[ ______ ] - 2100–2400 mm (optimum).
  -Finish:
[Formica high pressure laminate].
[Polished stainless steel].
[Perstop, RAL colour]. - Insert colour requirements.
 Inset window glazing:
[6 mm laminated safety glass].
[24 mm double glazed].
[Windows with UK absorbing foil materials].
 Sound insulation:
[ ______ ] - Up to 32 dB possible; consult manufacturer and insert requirements.
 X-Ray shielding:
[Not required].
[Required].
 Frame:
[Single]. - Made from aluminium profile sections.
[Double]. - Aluminium profile sections with intermediate section to match door wing.
 Control:
[D-Bedix hard wired control unit].
[F Key].
[Large optical push pad].


top ^

Guidance

for SLX/D Hermetically Sealed Automatic Sliding Door

from Gilgen Door Systems UK Ltd

More about SLX/D Hermetically Sealed Automatic Sliding Door: As standard - Options - Approvals - Further information.

As standard

Drive system:

  • SLX Sliding door drive unit with pivoting mechanism that enables the sliding wing to be simultaneously lowered and pressed against the door frame during the closing motion.
  • Integrates Bluetooth wireless control technology and powerful, near silent drive into a very slender profile. System components are connected via a CANbus, which not only guarantees smooth and reliable operation, but also facilitates constant communication with the processor to ensure optimum operational safety.

Safety:

  • Combined presence and activation sensing devices ensure door opening distances are in accordance with BS EN 16005, prevent doors closing on pedestrians within the threshold area and provide a signal to the door control system, thereby optimising pedestrian safety.
  • Rear edge sensors (electro sensitive protection equipment, ESPE) complying with BS EN 16005 are located within the door operator to maintain back of door safety and protect pedestrians against crushing edges at the main closing edge.
  • Fail-safe system (battery back-up) enables up to 30 minutes operation (subject to use) in the event of a mains failure. The fail safe system is automatically tested at least once every 24 hours.
  • Fire alarm interface connection enables door leaves to fail safe to open in the event of an emergency. In compliance with BS EN 16005 door sets with a clear opening width of up to 2000 mm open by at least 80% within 3 seconds after activation by the activators in the escape direction (or within 5 seconds in the event of the loss of power.)

Water resistance:

IP20 rating.

Operation:

24 V DC motor with microprocessor controller which allows extensive options for opening width, electric locking, summer/ winter modes, exit only, manual control, speed of opening and the length of time the door is open.

Power requirements:

230 V single phase. A 13 A live neon-lit fused spur supply, protected by a 30 mA RCD must be provided prior to installation. In order to comply with BS EN 16005 the mains connection must be capable of disconnection to prevent unintentional and unauthorised reactivation.

Door panel weight (maximum):

120 kg.

Options

Control:

  • Portable Bedix wireless control unit: Designed to enable selection of operating modes and configure parameters. Simple menu based controls. No fixed location required. Password protected.
  • D-Bedix hard wired programming key pad with digital display. Designed for installing a central control panel. Configured or Automatic – Night – Exit – Open door operating modes.
  • F Key: Each unit can be programmed to restrict access to areas which normally need to be kept locked.

Operation:

  • Additionally, the door allows for fitting of door position switches, fire or smoke alarm signals and voice message systems to assist partially sighted people and integrates with access control systems.

X-Ray shielding:

With lead insert and special window.

Approvals

  • CE approval .
  • TUV NORD .
  • British Standards Institution: DIN18650-1 and DIN 18650-2 (2005 and 2010). British Standards Institution
  • British Standards Institution: EN 12207 Class 2 Air permeability. British Standards Institution
  • British Standards Institution: ISO 9001: 2008. British Standards Institution

Further Information

Literature:


RIBA CPD

CPD information is available for Gilgen Door Systems UK Ltd from ribacpd.com.

RIBA Product Selector

Additional information may be available for Gilgen Door Systems UK Ltd from ribaproductselector.com.

Contacts:

www.gilgendoorsystems.co.uk

info@gilgendoorsystems.co.uk

T: +44 (0)800 316 6994

F: +44 (0)800 316 6995

top ^

 

View larger image of SLX/ PSX Bi-Parting Sliding Door System from Gilgen Door Systems UK LtdSLX Automatic Sliding Door System

Gilgen SLX sliding door operators are designed, constructed and installed to satisfy BS EN 16005:2012, and are tested for one million cycles, providing proven reliability. The operators also comply with Building Regulations (E&W) Approved Document B and M, The Equality Act 2010 and BS 8300:2009.The integration of a number of technological advancements such as CanBus technology for enhanced operational safety and bluetooth wireless technology for easier access and control ensure the doors are suitability for a wide variety of applications such as retail, hotels, offices, airports, stations, hospitals, schools, colleges, garden centres and leisure.All equipment is installed by Automatic Door Suppliers Association (ADSA) accredited engineers.Door profile:40 mm thick.Drive system:SLX sliding door drive system integrates Bluetooth wireless control technology and a powerful, near silent drive into a very slender profile. System components are connected via a can-bus, which not only guarantees smooth and reliable operation, but also facilitates constant communication with the processor to ensure optimum operational safety.Safety:Combined presence and activation sensing devices ensure door opening distances are in accordance with BS EN 16005, prevent doors closing on pedestrians within the threshold area and provide a signal to the door control system, thereby optimising pedestrian safety.Rear edge sensors (electro sensitive protection equipment, ESPE) complying with BS EN 16005 are located within the door operator to maintain back of door safety and protect pedestrians against crushing edges at the main closing edge.Fail-safe system (battery back-up) enables up to 30 minutes operation (subject to use) in the event of a mains failure. The fail safe system is automatically tested at least once every 24 hours.Fire alarm interface connection enables door leaves to fail safe to open in the event of an emergency. In compliance with BS EN 16005 door sets with a clear opening width of up to 2000 mm open by at least 80% within 3 seconds after activation by the activators in the escape direction (or within 5 seconds in the event of the loss of power.)Operation:24 V DC motor with microprocessor controller which allows extensive options for opening width, electric locking, summer/ winter modes, exit only, manual control, speed of opening and the length of time the door is open. Power requirements:230 V single phase. A 13 A live neon-lit fused spur supply, protected by a 30 mA RCD must be provided prior to installation. In order to comply with BS EN 16005 the mains connection must be capable of disconnection to prevent unintentional and unauthorised reactivation.Door leaf: - Width:Single sliding:Standard SLX drive: 700–2000 mm.Heavy duty SLX drive: 800–3000 mm.Heavy duty SLX drive with booster: 1100–3000 mm.Bi parting:Standard SLX drive: 800–3000 mm.Standard SLX drive with booster: 1000–3000 mm.Standard SLX drive dual motor: 1100–3000 mm.Heavy duty SLX drive dual motor: 1200–4000 mm.Standard SLX drive with break out: 1000–2500 mm. - Height:2000–3000 mm - Nominal depending upon location and door panel width and weight.- Weight:1 x 150 kg (standard SLX drive).1 x 240 kg (heavy duty SLX drive).1 x 400 kg (heavy duty SLX drive with booster).2 x 120 kg (standard SLX drive).2 x 150 kg (standard SLX drive plus booster or dual motor).2 x 240 kg (heavy duty SLX drive dual motor). - Configuration (break out solutions only):The bi-parting sliding door system with break out is designed to provide a convenient, barrier free access in day-to-day situations, while guaranteeing a safe exit for occupants and easy entry for emergency services in the event of a fire. In compliance with BS EN 16005 door leaves (or door set leaves and side screens) are capable of being broken out from any position in the direction of escape. The total force to release the break out function does not exceed 220 N.Rear door safety:Several options are available, subject to installation considerations. Please consult the manufacturer. The options available are;900 mm high, firmly secured, solid glazed barrier, in accordance with BS EN 16005.2.5 m high, fully glazed pocket screen complying with BS EN 16005.Security:A key turn manual hook lock (with steel insert in the leading edge for improved security and strength) is included as standard however there are a range of options available such as in head electric locks and multi point locking for added security. Integration with access control systems is also achievable. Please consult manufacturer. Control:D Bedix hard wired programming key pad (incorporating digital display screen). Designed for installation in a central control panel. Configured for Automatic/ Manual/ Night/ Exit/ Open door operating modes.Portable Bedix wireless control unit designed to enable selection of operating modes (as per D Bedix) and configure parameters. Simple menu based controls. No fixed location required. Password protected.Kombi D Bedix, push button control (as standard D Bedix) incorporating additional security key to prevent unauthorized access.F Key: Multi user, compact programmable portable unit enabling restricted personnel access.Six position key switch. Single point door control but with NO fault identification.Operation:Additionally, the door allows for fitting of door position switches, fire or smoke alarm signals and voice message systems to assist partially sighted people and integrates with access control systems.Glazing:Single or double glazed with a range of U-values as low as 1.6 W/m²K.Tinted glazing.For added security glazing complete with bomb blast resistant film can readily be supplied.Glazing complete with etched in logos. Glazed fan lights.Door movement guide:Surface mounted fixed point guide enhances efficiency of door movement.Recessed floor track, helps further improve door security as well as improved weather sealing and resistance to strong winds and driving rain. Recessed floor track:Helps further improve door security as well as improved weather sealing and resistance to strong winds and driving rain. Product literature:http://www.ribaproductselector.com/documentdetails.aspx?ci=03743&f=COL345157.pdf&pg=40CE approved0TUV NORD 10DIN18650-1 and DIN 18650-2 2005 and 201010ISO 9001: 2008

Gilgen SLX sliding door operators are designed, constructed and installed to satisfy BS EN 16005:2012, and are tested for one million cycles, providing proven reliability. The operators also comply with Building Regulations (E&W) Approved Document B and M, The Equality Act 2010 and BS 8300:2009.

The integration of a number of technological advancements such as CanBus technology for enhanced operational safety and bluetooth wireless technology for easier access and control ensure the doors are suitability for a wide variety of applications such as retail, hotels, offices, airports, stations, hospitals, schools, colleges, garden centres and leisure.

All equipment is installed by Automatic Door Suppliers Association (ADSA) accredited engineers.

More about SLX Automatic Sliding Door System:
As standard - Options - Approvals - Further information.

PendingAUTOMATIC SLIDING DOOR:
 Manufacturer:
Gilgen Door Systems UK Ltd.
  -Web:www.gilgendoorsystems.co.uk.
  -Tel:+44 (0)800 316 6994.
  -Product reference:
SLX Automatic Sliding Door System.
 Door:
  -Configuration:
[Bi-parting, no fixed panels].
[Bi-parting, two fixed glazed panels].
[Bi-parting with full emergency break out (doors and glazed screens)].
  -Clearance width:
[ ______ ] - 700–3000 mm single sliding; 800–4000 mm bi-parting; 1000–2500 mm bi-parting models with break out.
  -Height:
[ ______ ] - 2000–3000 mm; insert requirements.
  -Midrail:
[Not required].
[Required]. - Consult manufacturer for details.
 Finish:
[Polyester powder coated, RAL]. - Insert colour requirements.
[Silver anodized].
[Stainless steel cladding, brushed].
 Drive operation:
[Standard SLX].
[Standard SLX plus booster].
[Standard SLX drive plus dual motor].
 Glazing:
[ ______ ] - Installation specific; please consult manufacturer and insert requirements.
 Control:
[D Bedix hard wired control unit].
[F key].
[Kombi D Bedix].
 Activation:
[Integration with access control systems].
[Manual push pad].
[Motion sensors].
 Locking and security:
[ ______ ] - Installation specific; please consult manufacturer and insert requirements.
 Door movement guide:
[Recessed floor track]. - Not suitable if break out option required.
[Surface mounted fixed point guide].
 Rear door safety:
[ ______ ] - Installation specific please consult manufacturer.


top ^

Guidance

for SLX Automatic Sliding Door System

from Gilgen Door Systems UK Ltd

More about SLX Automatic Sliding Door System: As standard - Options - Approvals - Further information.

As standard

Door profile:

40 mm thick.

Drive system:

SLX sliding door drive system integrates Bluetooth wireless control technology and a powerful, near silent drive into a very slender profile. System components are connected via a can-bus, which not only guarantees smooth and reliable operation, but also facilitates constant communication with the processor to ensure optimum operational safety.

Safety:

  • Combined presence and activation sensing devices ensure door opening distances are in accordance with BS EN 16005, prevent doors closing on pedestrians within the threshold area and provide a signal to the door control system, thereby optimising pedestrian safety.
  • Rear edge sensors (electro sensitive protection equipment, ESPE) complying with BS EN 16005 are located within the door operator to maintain back of door safety and protect pedestrians against crushing edges at the main closing edge.
  • Fail-safe system (battery back-up) enables up to 30 minutes operation (subject to use) in the event of a mains failure. The fail safe system is automatically tested at least once every 24 hours.
  • Fire alarm interface connection enables door leaves to fail safe to open in the event of an emergency. In compliance with BS EN 16005 door sets with a clear opening width of up to 2000 mm open by at least 80% within 3 seconds after activation by the activators in the escape direction (or within 5 seconds in the event of the loss of power.)

Operation:

24 V DC motor with microprocessor controller which allows extensive options for opening width, electric locking, summer/ winter modes, exit only, manual control, speed of opening and the length of time the door is open.

Power requirements:

230 V single phase. A 13 A live neon-lit fused spur supply, protected by a 30 mA RCD must be provided prior to installation. In order to comply with BS EN 16005 the mains connection must be capable of disconnection to prevent unintentional and unauthorised reactivation.

Options

Door leaf:

- Width:

Single sliding:

  • Standard SLX drive: 700–2000 mm.
  • Heavy duty SLX drive: 800–3000 mm.
  • Heavy duty SLX drive with booster: 1100–3000 mm.

Bi parting:

  • Standard SLX drive: 800–3000 mm.
  • Standard SLX drive with booster: 1000–3000 mm.
  • Standard SLX drive dual motor: 1100–3000 mm.
  • Heavy duty SLX drive dual motor: 1200–4000 mm.
  • Standard SLX drive with break out: 1000–2500 mm.

- Height:

2000–3000 mm - Nominal depending upon location and door panel width and weight.

- Weight:

  • 1 x 150 kg (standard SLX drive).
  • 1 x 240 kg (heavy duty SLX drive).
  • 1 x 400 kg (heavy duty SLX drive with booster).
  • 2 x 120 kg (standard SLX drive).
  • 2 x 150 kg (standard SLX drive plus booster or dual motor).
  • 2 x 240 kg (heavy duty SLX drive dual motor).

- Configuration (break out solutions only):

The bi-parting sliding door system with break out is designed to provide a convenient, barrier free access in day-to-day situations, while guaranteeing a safe exit for occupants and easy entry for emergency services in the event of a fire. In compliance with BS EN 16005 door leaves (or door set leaves and side screens) are capable of being broken out from any position in the direction of escape. The total force to release the break out function does not exceed 220 N.

Rear door safety:

Several options are available, subject to installation considerations. Please consult the manufacturer. The options available are;

  • 900 mm high, firmly secured, solid glazed barrier, in accordance with BS EN 16005.
  • 2.5 m high, fully glazed pocket screen complying with BS EN 16005.

Security:

A key turn manual hook lock (with steel insert in the leading edge for improved security and strength) is included as standard however there are a range of options available such as in head electric locks and multi point locking for added security. Integration with access control systems is also achievable. Please consult manufacturer.

Control:

  • D Bedix hard wired programming key pad (incorporating digital display screen). Designed for installation in a central control panel. Configured for Automatic/ Manual/ Night/ Exit/ Open door operating modes.
  • Portable Bedix wireless control unit designed to enable selection of operating modes (as per D Bedix) and configure parameters. Simple menu based controls. No fixed location required. Password protected.
  • Kombi D Bedix, push button control (as standard D Bedix) incorporating additional security key to prevent unauthorized access.
  • F Key: Multi user, compact programmable portable unit enabling restricted personnel access.
  • Six position key switch. Single point door control but with NO fault identification.

Operation:

Additionally, the door allows for fitting of door position switches, fire or smoke alarm signals and voice message systems to assist partially sighted people and integrates with access control systems.

Glazing:

  • Single or double glazed with a range of U-values as low as 1.6 W/m²K.
  • Tinted glazing.
  • For added security glazing complete with bomb blast resistant film can readily be supplied.
  • Glazing complete with etched in logos.
  • Glazed fan lights.

Door movement guide:

  • Surface mounted fixed point guide enhances efficiency of door movement.
  • Recessed floor track, helps further improve door security as well as improved weather sealing and resistance to strong winds and driving rain.

Recessed floor track:

Helps further improve door security as well as improved weather sealing and resistance to strong winds and driving rain.

Approvals

  • CE approved .
  • TUV NORD .
  • British Standards Institution: DIN18650-1 and DIN 18650-2 2005 and 2010. British Standards Institution
  • British Standards Institution: ISO 9001: 2008. British Standards Institution

Further Information

Literature:


RIBA CPD

CPD information is available for Gilgen Door Systems UK Ltd from ribacpd.com.

RIBA Product Selector

Additional information may be available for Gilgen Door Systems UK Ltd from ribaproductselector.com.

Contacts:

www.gilgendoorsystems.co.uk

info@gilgendoorsystems.co.uk

T: +44 (0)800 316 6994

F: +44 (0)800 316 6995

top ^

 

View larger image of SLX/ PSX Telescopic 2 Wing Sliding Door System from Gilgen Door Systems UK LtdSLX Telescopic Sliding Door System

Gilgen SLX telescopic sliding doors maximise the clear walk through width of entrances through extending door leafs. Achieving a wider opening than standard bi-parting doors they are ideal for high volumes of pedestrian traffic such as transport hubs. The design also helps to provide protection from draughts and conserve energy. Gilgen SLX operators are designed, constructed and installed to satisfy BS EN 16005:2012, and are tested for one million cycles, providing proven reliability. The operators also comply with Building Regulations (E&W) Approved Document B and M, The Equality Act 2010 and BS 8300:2009.The integration of a number of technological advancements such as CanBus technology for enhanced operational safety and Bluetooth wireless technology for easier access and control, ensure suitability for a wide variety of applications.All equipment is installed by Automatic Door Suppliers Association (ADSA) accredited engineers.Door profile:40 mm thick.Drive system:SLX/ PSX sliding door drive system integrates Bluetooth wireless control technology and a powerful, near silent drive into a very slender in profile. System components are connected via a can-bus, which not only guarantees smooth and reliable operation, but also facilitates constant communication with the processor to ensure optimum operational safety.Safety:Combined presence and activation sensing devices ensure door opening distances are in accordance with BS EN 16005, prevent doors closing on pedestrians within the threshold area and provide a signal to the door control system, thereby optimising pedestrian safety.Rear edge sensors (electro sensitive protection equipment, ESPE) complying with BS EN 16005 are located within the door operator to maintain back of door safety and protect pedestrians against crushing edges at the main closing edge.Fail-safe system (battery back-up) enables up to 30 minutes operation (subject to use) in the event of a mains failure. The fail safe system is automatically tested at least once every 24 hours.Fire alarm interface connection enables door leaves to fail safe to open in the event of an emergency. In compliance with BS EN 16005 door sets with a clear opening width of up to 2000 mm open by at least 80% within 3 seconds after activation by the activators in the escape direction (or within 5 seconds in the event of the loss of power.)Operation:24 VDC motor with microprocessor controller which allows extensive options for opening width, electric locking, summer/ winter modes, exit only, manual control, speed of opening and the length of time the door is open. Power requirements:230 V single phase. A 13 A live neon-lit fused spur supply, protected by a 30 mA RCD must be provided prior to installation. In order to comply with BS EN 16005 the mains connection must be capable of disconnection to prevent unintentional and unauthorised reactivation.Door clearance width: – Single sliding, two wing:Standard SLX drive: 1100–3000 mm.Standard SLX drive plus booster: 1400–3000 mm. – Bi-parting, four wing:Standard SLX drive: 1200–4000 mm.Standard SLX drive plus booster: 1400–4000 mm.Standard SLX drive plus dual motor: 2050–4000 mm.Height:2000–3000 mm - Nominal depending upon location and door panel width and weight.Door panel weight:Standard drive: 2 x 120 kg.Standard drive plus booster: 2 x 150 kg.Standard SLX drive: 4 x 60 kg.Standard SLX drive plus booster or dual motor: 4 x 100 kg).Security:A key turn manual hook lock (with steel insert in the leading edge for improved security and strength) is included as standard however there are a range of options available such as in head electric locks and multi point locking for added security. Integration with access control systems is also achievable. Please consult manufacturer.Control:D Bedix hard wired programming key pad (incorporating digital display screen) designed for installation in a central control panel. Configured for automatic/ manual/ night/ exit/ open door operating modes. Portable Bedix wireless control unit designed to enable selection of operating modes (as per D Bedix) and configure parameters. Simple menu based controls. No fixed location required. Password protectedKombi D Bedix, push button control (as standard D Bedix) incorporating additional security key to prevent unauthorized accessF Key: Multi user, compact programmable portable unit enabling restricted personnel access.Six position key switch. Single point door control but with NO fault identificationOperation:Additionally, the door allows for fitting of door position switches, fire or smoke alarm signals and voice message systems to assist partially sighted people and integrates with access control systems.Glazing:Single or double glazed with a range of U-values as low as 1.6 W/m²K.Tinted glazing.For added security glazing complete with bomb blast resistant film can readily be supplied.Glazing complete with etched in logos. Glazed fan lights.Door movement guide:Surface mounted fixed point guide enhances efficiency of door movement.Recessed floor track, helps further improve door security as well as improved weather sealing and resistance to strong winds and driving rain. 0CEApproved0TUV NORD10DIN18650-1 and DIN 18650-2 (2005 and 2010)10ISO 9001: 2008

Gilgen SLX telescopic sliding doors maximise the clear walk through width of entrances through extending door leafs. Achieving a wider opening than standard bi-parting doors they are ideal for high volumes of pedestrian traffic such as transport hubs. The design also helps to provide protection from draughts and conserve energy. Gilgen SLX operators are designed, constructed and installed to satisfy BS EN 16005:2012, and are tested for one million cycles, providing proven reliability. The operators also comply with Building Regulations (E&W) Approved Document B and M, The Equality Act 2010 and BS 8300:2009.

The integration of a number of technological advancements such as CanBus technology for enhanced operational safety and Bluetooth wireless technology for easier access and control, ensure suitability for a wide variety of applications.

All equipment is installed by Automatic Door Suppliers Association (ADSA) accredited engineers.

More about SLX Telescopic Sliding Door System:
As standard - Options - Approvals - Further information.

PendingAUTOMATIC SLIDING DOOR:
 Manufacturer:
Gilgen Door Systems UK Ltd.
  -Web:www.gilgendoorsystems.co.uk.
  -Tel:+44 (0)800 316 6994.
  -Product reference:
SLX Telescopic Sliding Door System.
 Door:
  -Configuration:
[Bi parting 4 leaf telescopic slide, no fixed panels].
[Bi parting 4 leaf telescopic slide, two fixed panels].
[Single sliding 2 leaf telescopic slide, no fixed panels].
  -Clearance width:
[ ______ ] - 2050–4000 mm; insert requirements.
  -Height:
[ ______ ] - 2100–3000 mm; insert requirements.
 Finish:
[Silver anodized].
[Polyester powder coated, RAL]. - Insert requirements.
[Stainless steel cladding, brushed].
 Drive operation:
[Standard SLX].
[Standard SLX plus booster].
[Standard SLX drive plus dual motor].
 Glazing:
[ ______ ] - Installation specific; please consult manufacturer and insert requirements.
 Control:
[D Bedix hard wired control unit].
[F key].
[Kombi D Bedix].
 Activation:
[Integration with access control systems].
[Manual push pad].
[Motion sensors].
 Locking and security:
[ ______ ] - Installation specific; please consult manufacturer and insert requirements.
 Door movement guide:
[Recessed floor track].
[Surface mounted fixed point guide].
 Rear door safety:
[Rear edge safety senors].


top ^

Guidance

for SLX Telescopic Sliding Door System

from Gilgen Door Systems UK Ltd

More about SLX Telescopic Sliding Door System: As standard - Options - Approvals - Further information.

As standard

Door profile:

40 mm thick.

Drive system:

SLX/ PSX sliding door drive system integrates Bluetooth wireless control technology and a powerful, near silent drive into a very slender in profile. System components are connected via a can-bus, which not only guarantees smooth and reliable operation, but also facilitates constant communication with the processor to ensure optimum operational safety.

Safety:

  • Combined presence and activation sensing devices ensure door opening distances are in accordance with BS EN 16005, prevent doors closing on pedestrians within the threshold area and provide a signal to the door control system, thereby optimising pedestrian safety.
  • Rear edge sensors (electro sensitive protection equipment, ESPE) complying with BS EN 16005 are located within the door operator to maintain back of door safety and protect pedestrians against crushing edges at the main closing edge.
  • Fail-safe system (battery back-up) enables up to 30 minutes operation (subject to use) in the event of a mains failure. The fail safe system is automatically tested at least once every 24 hours.
  • Fire alarm interface connection enables door leaves to fail safe to open in the event of an emergency. In compliance with BS EN 16005 door sets with a clear opening width of up to 2000 mm open by at least 80% within 3 seconds after activation by the activators in the escape direction (or within 5 seconds in the event of the loss of power.)

Operation:

24 VDC motor with microprocessor controller which allows extensive options for opening width, electric locking, summer/ winter modes, exit only, manual control, speed of opening and the length of time the door is open.

Power requirements:

230 V single phase. A 13 A live neon-lit fused spur supply, protected by a 30 mA RCD must be provided prior to installation. In order to comply with BS EN 16005 the mains connection must be capable of disconnection to prevent unintentional and unauthorised reactivation.

Options

Door clearance width:

– Single sliding, two wing:

  • Standard SLX drive: 1100–3000 mm.
  • Standard SLX drive plus booster: 1400–3000 mm.

– Bi-parting, four wing:

  • Standard SLX drive: 1200–4000 mm.
  • Standard SLX drive plus booster: 1400–4000 mm.
  • Standard SLX drive plus dual motor: 2050–4000 mm.

Height:

2000–3000 mm - Nominal depending upon location and door panel width and weight.

Door panel weight:

  • Standard drive: 2 x 120 kg.
  • Standard drive plus booster: 2 x 150 kg.
  • Standard SLX drive: 4 x 60 kg.
  • Standard SLX drive plus booster or dual motor: 4 x 100 kg).

Security:

A key turn manual hook lock (with steel insert in the leading edge for improved security and strength) is included as standard however there are a range of options available such as in head electric locks and multi point locking for added security. Integration with access control systems is also achievable. Please consult manufacturer.

Control:

  • D Bedix hard wired programming key pad (incorporating digital display screen) designed for installation in a central control panel. Configured for automatic/ manual/ night/ exit/ open door operating modes.
  • Portable Bedix wireless control unit designed to enable selection of operating modes (as per D Bedix) and configure parameters. Simple menu based controls. No fixed location required. Password protected
  • Kombi D Bedix, push button control (as standard D Bedix) incorporating additional security key to prevent unauthorized access
  • F Key: Multi user, compact programmable portable unit enabling restricted personnel access.
  • Six position key switch. Single point door control but with NO fault identification

Operation:

Additionally, the door allows for fitting of door position switches, fire or smoke alarm signals and voice message systems to assist partially sighted people and integrates with access control systems.

Glazing:

  • Single or double glazed with a range of U-values as low as 1.6 W/m²K.
  • Tinted glazing.
  • For added security glazing complete with bomb blast resistant film can readily be supplied.
  • Glazing complete with etched in logos.
  • Glazed fan lights.

Door movement guide:

  • Surface mounted fixed point guide enhances efficiency of door movement.
  • Recessed floor track, helps further improve door security as well as improved weather sealing and resistance to strong winds and driving rain.

Approvals

  • CE: Approved.
  • TUV NORD .
  • British Standards Institution: DIN18650-1 and DIN 18650-2 (2005 and 2010). British Standards Institution
  • British Standards Institution: ISO 9001: 2008. British Standards Institution

Further Information

Literature:

RIBA CPD

CPD information is available for Gilgen Door Systems UK Ltd from ribacpd.com.

RIBA Product Selector

Additional information may be available for Gilgen Door Systems UK Ltd from ribaproductselector.com.

Contacts:

www.gilgendoorsystems.co.uk

info@gilgendoorsystems.co.uk

T: +44 (0)800 316 6994

F: +44 (0)800 316 6995

top ^

 

View larger image of SLX/ PSW Energy Efficient Automatic Sliding Door System from Gilgen Door Systems UK LtdSLX/ PSW Energy Efficient Automatic Sliding Door System

Gilgen SLX sliding door operators are designed, constructed and installed to satisfy BS EN 16005:2012, and are tested for one million cycles, providing proven reliability. The operators also comply with Building Regulations (E&W) Approved Documents B and M of the Building Regulations (England and Wales), The Equality Act 2010 and BS 8300:2009.The thermally insulated PSW profile system has been successfully tested in accordance to BS EN 14351-2 thereby enabling energy efficient automatic doors that not only enable very low U-values (1.5 W/m²K) to be achieved but also provide air permeability Class 2 in accordance with BS EN 12207 and Class 5A water tightness in accordance with BS EN 12208.SLX / PSW are suitable for high volume, heavy duty, retail trade, hotels, offices, airports, stations, hospitals, schools, colleges, garden centres and leisure.All equipment is installed by Automatic Door Suppliers Association (ADSA) accredited engineers.Drive system:SLX-M sliding door drive system integrates Bluetooth wireless control technology and a powerful, near silent drive into a very slender in profile. System components are connected via a can-bus, which not only guarantees smooth and reliable operation, but also facilitates constant communication with the processor to ensure optimum operational safety.Safety:Combined presence and activation sensing devices ensure door opening distances are in accordance with BS EN 16005, prevent doors closing on pedestrians within the threshold area and provide a signal to the door control system, thereby optimising pedestrian safety.Rear edge sensors (electro sensitive protection equipment, ESPE) complying with BS EN 16005 are located within the door operator to maintain back of door safety and protect pedestrians against crushing edges at the main closing edge.Fail-safe system (battery back-up) enables up to 30 minutes operation (subject to use) in the event of a mains failure. The fail safe system is automatically tested at least once every 24 hours.Fire alarm interface connection enables door leaves to fail safe to open in the event of an emergency. In compliance with BS EN 16005 door sets with a clear opening width of up to 2000 mm open by at least 80% within 3 seconds after activation by the activators in the escape direction (or within 5 seconds in the event of the loss of power.)Operation:24V DC motor with microprocessor controller which allows extensive options for opening width, electric locking, summer/ winter modes, exit only, manual control, speed of opening and the length of time the door is open. Door weight:Single sliding doors: 1 x 150 kg.Bi-parting doors: 2 x 250 kg.Power requirements:230 V single phase. A 13 A live neon-lit fused spur supply, protected by a 30 mA RCD must be provided prior to installation. In order to comply with BS EN 16005 the mains connection must be capable of disconnection to prevent unintentional and unauthorised reactivation.Rear door safety:Several options are available, subject to installation considerations. Please consult the manufacturer. The options available are;900 mm high, firmly secured, solid glazed barrier, in accordance with BS EN 16005.2.5 m high, fully glazed pocket screen complying with BS EN 16005.Control:D Bedix hard wired programming key pad (incorporating digital display screen) designed for installation in a central control panel. Configured for automatic/ manual/ night/ exit/ open door operating modes.Portable Bedix wireless control unit designed to enable selection of operating modes (as per D Bedix) and configure parameters. Simple menu based controls. No fixed location required. Password protected.Kombi D Bedix, push button control (as standard D Bedix) incorporating additional security key to prevent unauthorized access.F Key: Multi user, compact programmable portable unit enabling restricted personnel access.Six position key switch. Single point door control but with NO fault identification.Operation:Additionally, the door allows for fitting of door position switches, fire or smoke alarm signals, voice message systems to assist partially sighted people and integrates with access control systems.Door movement guide:Surface mounted fixed point guide enhances efficiency of door movement.Recessed floor track: Helps further improve door security as well as improved weather sealing and resistance to strong winds and driving rain. Product literature:http://www.ribaproductselector.com/documentdetails.aspx?ci=03743&f=COL345157.pdf&pg=50CE approval0TUV10Air permeability Class 2 in accordance with EN 1220710Class 5A water tightness in accordance with EN 12208

Gilgen SLX sliding door operators are designed, constructed and installed to satisfy BS EN 16005:2012, and are tested for one million cycles, providing proven reliability. The operators also comply with Building Regulations (E&W) Approved Documents B and M of the Building Regulations (England and Wales), The Equality Act 2010 and BS 8300:2009.

The thermally insulated PSW profile system has been successfully tested in accordance to BS EN 14351-2 thereby enabling energy efficient automatic doors that not only enable very low U-values (1.5 W/m²K) to be achieved but also provide air permeability Class 2 in accordance with BS EN 12207 and Class 5A water tightness in accordance with BS EN 12208.

SLX / PSW are suitable for high volume, heavy duty, retail trade, hotels, offices, airports, stations, hospitals, schools, colleges, garden centres and leisure.

All equipment is installed by Automatic Door Suppliers Association (ADSA) accredited engineers.

More about SLX/ PSW Energy Efficient Automatic Sliding Door System:
As standard - Options - Approvals - Further information.

PendingDOORSETS:
 Manufacturer:
Gilgen Door Systems UK Ltd.
  -Web:www.gilgendoorsystems.co.uk.
  -Tel:+44 (0)800 316 6994.
  -Product reference:
SLX/ PSW Energy Efficient Automatic Sliding Door System.
 Door :
  -Configuration:
[Bi parting no fixed side panels].
[Bi parting two fixed side panels].
[Bi-parting, two fixed panels and fan light].
  -Clearance width:
[ ______ ] - 700–2000 mm (single sliding); 800–3000 mm (bi-parting).
  -Height:
[ ______ ] - 2100–3000 mm; insert requirements.
 Finish:
[Polyester powder coated, RAL]. - Insert colour requirements.
 Glazing:
[ ______ ] - Insulating glass, 24–50 mm thickness. Installation specific – please consult manufacturer and insert requirements.
  -Control:
[D Bedix hard wired control unit].
[F Key].
[Kombi D Bedix].
 Activation:
[Integration with access control systems].
[Manual push pad].
[Motion sensors].
 Locking and security:
[Standard].
[Multipoint].
 Door movement guide:
[Recessed floor track].
[Surface mounted fixed point guide].
 Rear door safety:
[ ______ ] - Installation specific please consult manufacturer.


top ^

Guidance

for SLX/ PSW Energy Efficient Automatic Sliding Door System

from Gilgen Door Systems UK Ltd

More about SLX/ PSW Energy Efficient Automatic Sliding Door System: As standard - Options - Approvals - Further information.

As standard

Drive system:

SLX-M sliding door drive system integrates Bluetooth wireless control technology and a powerful, near silent drive into a very slender in profile. System components are connected via a can-bus, which not only guarantees smooth and reliable operation, but also facilitates constant communication with the processor to ensure optimum operational safety.

Safety:

  • Combined presence and activation sensing devices ensure door opening distances are in accordance with BS EN 16005, prevent doors closing on pedestrians within the threshold area and provide a signal to the door control system, thereby optimising pedestrian safety.
  • Rear edge sensors (electro sensitive protection equipment, ESPE) complying with BS EN 16005 are located within the door operator to maintain back of door safety and protect pedestrians against crushing edges at the main closing edge.
  • Fail-safe system (battery back-up) enables up to 30 minutes operation (subject to use) in the event of a mains failure. The fail safe system is automatically tested at least once every 24 hours.
  • Fire alarm interface connection enables door leaves to fail safe to open in the event of an emergency. In compliance with BS EN 16005 door sets with a clear opening width of up to 2000 mm open by at least 80% within 3 seconds after activation by the activators in the escape direction (or within 5 seconds in the event of the loss of power.)

Operation:

24V DC motor with microprocessor controller which allows extensive options for opening width, electric locking, summer/ winter modes, exit only, manual control, speed of opening and the length of time the door is open.

Door weight:

  • Single sliding doors: 1 x 150 kg.
  • Bi-parting doors: 2 x 250 kg.

Power requirements:

230 V single phase. A 13 A live neon-lit fused spur supply, protected by a 30 mA RCD must be provided prior to installation. In order to comply with BS EN 16005 the mains connection must be capable of disconnection to prevent unintentional and unauthorised reactivation.

Options

Rear door safety:

Several options are available, subject to installation considerations. Please consult the manufacturer. The options available are;

  • 900 mm high, firmly secured, solid glazed barrier, in accordance with BS EN 16005.
  • 2.5 m high, fully glazed pocket screen complying with BS EN 16005.

Control:

  • D Bedix hard wired programming key pad (incorporating digital display screen) designed for installation in a central control panel. Configured for automatic/ manual/ night/ exit/ open door operating modes.
  • Portable Bedix wireless control unit designed to enable selection of operating modes (as per D Bedix) and configure parameters. Simple menu based controls. No fixed location required. Password protected.
  • Kombi D Bedix, push button control (as standard D Bedix) incorporating additional security key to prevent unauthorized access.
  • F Key: Multi user, compact programmable portable unit enabling restricted personnel access.
  • Six position key switch. Single point door control but with NO fault identification.

Operation:

Additionally, the door allows for fitting of door position switches, fire or smoke alarm signals, voice message systems to assist partially sighted people and integrates with access control systems.

Door movement guide:

Surface mounted fixed point guide enhances efficiency of door movement.

Recessed floor track:

Helps further improve door security as well as improved weather sealing and resistance to strong winds and driving rain.

Approvals

  • CE approval .
  • TUV .
  • British Standards Institution: Air permeability Class 2 in accordance with EN 12207. British Standards Institution
  • British Standards Institution: Class 5A water tightness in accordance with EN 12208. British Standards Institution

Further Information

Literature:


RIBA CPD

CPD information is available for Gilgen Door Systems UK Ltd from ribacpd.com.

RIBA Product Selector

Additional information may be available for Gilgen Door Systems UK Ltd from ribaproductselector.com.

Contacts:

www.gilgendoorsystems.co.uk

info@gilgendoorsystems.co.uk

T: +44 (0)800 316 6994

F: +44 (0)800 316 6995

top ^

 

View larger image of FFM 4 Wing Bi-Part Folding Door System from Gilgen Door Systems UK LtdFFM 4 Wing Bi-Part Folding Door System

The FFM 4 Wing Bi-Part Folding Door System is designed, constructed and installed to satisfy BS EN 16005:2012, and also complies with the Building Regulations (E&W) Approved Document M, The Equality Act 2010 and BS 8300:2009.The system requires a minimum of installation space, yet offers maximum clearance width. It is suitable for a wide variety of applications such as: retail, hotels, offices, airports, stations, hospitals, schools, colleges, garden centres and leisure.All Gilgen folding doors are supplied complete with a fail-safe system which gives up to 30 minutes operation in the event of a mains failure. The main drive unit also incorporates both an auto-reverse safety mechanism and safety stopping mechanisms.All equipment is installed by Automatic Door Suppliers Association (ADSA) accredited engineers.Door profile:40 mm thick.Drive system:FFM drive unit incorporating both auto reverse safety mechanism and safety stopping mechanisms.Safety:Combined presence and activation sensing devices ensure door opening distances are in accordance with BS EN 16005, prevent doors closing on pedestrians within the threshold area and provide a signal to the door control system, thereby optimising pedestrian safety.Rear edge sensors (electro sensitive protection equipment, ESPE) complying with BS EN 16005 are located within the door operator to maintain back of door safety and protect pedestrians against crushing edges at the main closing edge.Fail-safe system (battery back-up) enables up to 30 minutes operation (subject to use) in the event of a mains failure. The fail safe system is automatically tested at least once every 24 hours.Fire alarm interface connection enables door leaves to fail safe to open in the event of an emergency. In compliance with BS EN 16005 door sets with a clear opening width of up to 2000 mm open by at least 80% within 3 seconds after activation by the activators in the escape direction (or within 5 seconds in the event of the loss of power).Operation:24 V DC motor with microprocessor controller. Additionally, the door allows for fitting of door position switches, fire or smoke alarm signals, voice message systems to assist partially sighted people and integrates with access control systems.Control:Bedis hard wired programming key pad, designed for installation in a central control panel.Configured for Automatic/ Manual/ Summer/ Winter/ Night/ Exit/ Open door operating modes.Door weight:70 kg (per folding door leaf).Power requirements:230 V single phase. A 13 A live neon-lit fused spur supply, protected by a 30 mA RCD must be provided prior to installation. In order to comply with BS EN 16005 the mains connection must be capable of disconnection to prevent unintentional and unauthorised reactivation.Safety and security:A firmly secured, 900 mm high, solid glazed barrier can be provided at right angles to the threshold, in accordance with BS EN 16005.Mechanical lock incorporated within door operator supplied as standard. Additional options include:Bottom rail locks. External manual unlocking facility.Door movement guide:Recessed floor track, helps further improve door security as well as improved weather sealing and resistance to strong winds and driving rain. Product literature:http://www.ribaproductselector.com/documentdetails.aspx?ci=03743&f=COL405455.pdf&pg=10CE marked0TUV NORD 10DIN EN 60335-1:200710DIN18650-1 and DIN 18650-2 (2005 and 2010)10ISO 9001: 2008

The FFM 4 Wing Bi-Part Folding Door System is designed, constructed and installed to satisfy BS EN 16005:2012, and also complies with the Building Regulations (E&W) Approved Document M, The Equality Act 2010 and BS 8300:2009.

The system requires a minimum of installation space, yet offers maximum clearance width. It is suitable for a wide variety of applications such as: retail, hotels, offices, airports, stations, hospitals, schools, colleges, garden centres and leisure.

All Gilgen folding doors are supplied complete with a fail-safe system which gives up to 30 minutes operation in the event of a mains failure. The main drive unit also incorporates both an auto-reverse safety mechanism and safety stopping mechanisms.

All equipment is installed by Automatic Door Suppliers Association (ADSA) accredited engineers.

More about FFM 4 Wing Bi-Part Folding Door System:
As standard - Options - Approvals - Further information.

PendingAUTOMATIC DOOR OPERATOR:
 Manufacturer:
Gilgen Door Systems UK Ltd.
  -Web:www.gilgendoorsystems.co.uk.
  -Tel:+44 (0)800 316 6994.
  -Product reference:
FFM 4 Wing Bi-Part Folding Door System.
 Door configuration:
[Bi parting folding].
 Clearance width:
[ ______ ] - 800–1600 mm; insert requirements.
 Door height:
[ ______ ] - 2000–2500 mm; insert requirements.
 Finish:
[Anodized silver].
[Polyester powder coated RAL]. - Insert RAL colour reference.
 Glazing:
  -Configuration:
[Single glazed, 10 mm].
[Double glazed, 16 mm]. - Available on request.
  -Fanlights:
[Not required].
[Required]. - Insert size. Available height, 500–1000 mm.
 Control:
[Bedis hard wired control unit].
[Six position key switch]. - Optional.
 Activation:
[Integration with access control systems].
[Manual push pad].
[Motion sensors].
 Locking and security:
[ ______ ] - Installation specific; please consult manufacturer and insert requirements.
 Door movement guide:
[None].
[Recessed floor track]. - Available upon request.


top ^

Guidance

for FFM 4 Wing Bi-Part Folding Door System

from Gilgen Door Systems UK Ltd

More about FFM 4 Wing Bi-Part Folding Door System: As standard - Options - Approvals - Further information.

As standard

Door profile:

40 mm thick.

Drive system:

FFM drive unit incorporating both auto reverse safety mechanism and safety stopping mechanisms.

Safety:

  • Combined presence and activation sensing devices ensure door opening distances are in accordance with BS EN 16005, prevent doors closing on pedestrians within the threshold area and provide a signal to the door control system, thereby optimising pedestrian safety.
  • Rear edge sensors (electro sensitive protection equipment, ESPE) complying with BS EN 16005 are located within the door operator to maintain back of door safety and protect pedestrians against crushing edges at the main closing edge.
  • Fail-safe system (battery back-up) enables up to 30 minutes operation (subject to use) in the event of a mains failure. The fail safe system is automatically tested at least once every 24 hours.
  • Fire alarm interface connection enables door leaves to fail safe to open in the event of an emergency. In compliance with BS EN 16005 door sets with a clear opening width of up to 2000 mm open by at least 80% within 3 seconds after activation by the activators in the escape direction (or within 5 seconds in the event of the loss of power).

Operation:

24 V DC motor with microprocessor controller. Additionally, the door allows for fitting of door position switches, fire or smoke alarm signals, voice message systems to assist partially sighted people and integrates with access control systems.

Control:

  • Bedis hard wired programming key pad, designed for installation in a central control panel.
  • Configured for Automatic/ Manual/ Summer/ Winter/ Night/ Exit/ Open door operating modes.

Door weight:

70 kg (per folding door leaf).

Power requirements:

230 V single phase. A 13 A live neon-lit fused spur supply, protected by a 30 mA RCD must be provided prior to installation. In order to comply with BS EN 16005 the mains connection must be capable of disconnection to prevent unintentional and unauthorised reactivation.

Options

Safety and security:

A firmly secured, 900 mm high, solid glazed barrier can be provided at right angles to the threshold, in accordance with BS EN 16005.Mechanical lock incorporated within door operator supplied as standard. Additional options include:

  • Bottom rail locks.
  • External manual unlocking facility.

Door movement guide:

Recessed floor track, helps further improve door security as well as improved weather sealing and resistance to strong winds and driving rain.

Approvals

  • CE marked .
  • TUV NORD .
  • British Standards Institution: DIN EN 60335-1:2007. British Standards Institution
  • British Standards Institution: DIN18650-1 and DIN 18650-2 (2005 and 2010). British Standards Institution
  • British Standards Institution: ISO 9001: 2008. British Standards Institution

Further Information

Literature:


RIBA CPD

CPD information is available for Gilgen Door Systems UK Ltd from ribacpd.com.

RIBA Product Selector

Additional information may be available for Gilgen Door Systems UK Ltd from ribaproductselector.com.

Contacts:

www.gilgendoorsystems.co.uk

info@gilgendoorsystems.co.uk

T: +44 (0)800 316 6994

F: +44 (0)800 316 6995

top ^

 
Drag work item to add to schedule

top ^

 
NBS Plus
NBS Building, online library, 12 December 2017